Outlet Isolation Valve Mounting
•
WARNING Before removing valve from service, to avoid personal injury, you must:
• Depressurize the system
• Cycle the valve
• Purge system to remove any residual system media left in valve
The illustrations below identify all outlet isolation selections paired with their respective mounting brackets. To remove a valve
from the panel, first unscrew the 1/4 in. or 6 mm button head cap screws to remove the bracket from the main panel. The 1/4 in.
or 6 mm Swagelok tube fittings can then be loosened, and the valve and bracket are removed as a subassembly.
1/4-Turn Ball Valve
Multiturn Needle Valve
1/4-Turn Ball Valve (lockable)
No Outlet Isolation Valve
2× B.H.C.S.:
1/4-20 UNC × 3/8 in. Long
M6 × 1.0 × 10 mm Long
4× Set Screw:
No. 10-32 × 5/16 in. Long
M5 × 0.8 × 8 mm Long
2× B.H.C.S.:
1/4-20 UNC × 3/8 in. Long
M6 × 1.0 × 10 mm Long
2× B.H.C.S.:
1/4-20 UNC × 3/8 in. Long
M6 × 1.0 × 10 mm Long
2× B.H.C.S.:
1/4-20 UNC × 3/8 in. Long
M6 × 1.0 × 10 mm Long