background image

k

i

5 YEAR 

MOTOR WARRANTY

PREMIUM SENSORS POWERED BY SW SUN CONTROL

WIND CLIMATE SENSOR

WIND CLIMATE SENSOR

ATTENTION:

 before installing and using the sensor 

please read the instructions carefully. Before the 
installation check the compatibility of the device 
with the associated motors and controls.

SAFETY INSTRUCTIONS

• Risk of injury through an electric shock.
• Terminal connections to network must be made 
  by an authorised electrician.
• Disconnect all connecting cables throughout 
  the system before carrying out installation or 
 maintenance.
• Ensure that the device cannot be accidentally  
  switched on.
• Keep persons away from the systems operating 
 range.
• An automatically controlled sun protection  
  system can move unexpectedly. Therefore,   
  never place objects in the travel range.
• Keep children away from controls.
• Always observe country-specific regulations.
• If the system is controlled by one or more    
  devices, the system operating range must be  
  visible during operation.
• Always adhere to relevant building regulations.
• Automatic and manual movement when frozen  
  (e.g. frozen wind wheel) and during storms can  
  seriously damage the system.
• The receivers (e.g. radio control) no longer  
  function correctly after a power failure. In this  
  case, an extended sun protection system cannot 
  be retracted, e.g., during a storm.

Wireless climatic sensor 434.15MHz which controls radio motor/s for awnings according to weather 
conditions under stated thresholds.

IMPORTANT:

 this sensor does not protect the awnings against strong gusts of wind. When weather 

conditions presents this sort of risk, ensure that the awning remains closed.

INSTALLATION

Note: 

ensure that sensors are not installed close to metal surfaces, panes of metalised glass or 

generally magnetic fields can reduce the radio signals range.
Radio devices working on the same frequency could interfere with signals reception.

Select the right place for the installation of the sensor. Be careful that trees, roofs or parts of the 
building do not affect the light intensity and wind measurement.
The adjustable base of the sensor allows the right installation (

horizontal position

) on any surface

INSTALLATION

TECHNICAL DATA

Frequency (MHz)

434.15

Power Supply

120V - 60Hz

Wind Sensor (5 levels)

6 / 12 / 18 / 25 / 31 mph

Sun Sensor (4 levels)

5 / 20 / 40 / 60 Klux

Protection Rate

IP54

Coverage (int/ext)

65 ft

Working Temp (°F)

23° to 104°

Dimensions (in)

10.62 x 4.72 x 3.54

Weight (lbs)

0.14

WIRING CONNECTION

1.  Open the top cover by the 4 screws 
on the bottom.
2.  Connect the power line as described 
below. 

Check that the power supply 

corresponds to the label data.

3.  Close the top cover and tight the 
screw to seal it.

120V - 60Hz

Power Supply

  

Additional Accessories required: 

2-wire cable that meets the standards of the country in which it is installed 

Reviews: