![Svantek SVAN 979 User Manual Download Page 63](http://html.mh-extra.com/html/svantek/svan-979/svan-979_user-manual_1409285063.webp)
63
SVAN 979 User Manual
Changing display modes
Being in the measurement mode you can change the view mode with the
▲ / ▼
key pressed together with
<Alt>
.
5.1.1
Running SPL view
The
Running SPL
view is available in the Sound measurement modes. It
shows in a large format one measured result
– SPL for the selected profile (Leq
for the last second with the weighting filter and detector constant defined in the
Profiles
screen).
This result is not saved in a file and gives just the first assumption of the sound
level before the measurement.
The Running SPL view can be enabled and disabled in the
Display
screen.
You can hide or open this view with the
<ESC>
key.
You can change the displayed result with
the
◄ / ► key.
►
5.1.2
One Result view
The One Result view is always available in all measurement functions. You
cannot disable it. In this view, only one measured result is displayed in large
digits.
One Result view fields
1.
Logger file name.
2.
Profile number.
3.
Value of the measured result.
4.
Weighting filter:
Z
,
A
,
C
,
B
,
G
for Sound
measurements or
HP
,
HP1
,
HP3
,
HP10
,
Vel1
,
Vel3
,
Vel10
,
VelMF
,
Dil1
,
Dil3
,
Dil10
,
Wh
for
Vibration measurements.
5.
Detector type:
Lin
when
RMS Integration
is
Lin
(path: <Menu> / Measurement / General Settings)
or:
Imp.
,
Fast
,
Slow
for Sound measurements
or
100 ms
,
125 ms
,
.. 10.0 s
, for Vibration
measurements, when
RMS Integration
is
Log
.
6.
Units of the measured value.
7.
Result name:
Spl
,
Leq
,
SEL
,
Lden
,
LEPd
,
Ltm3
,
LTeq
,
Lnn
,
EX
,
SD
,
LR1
,
LR2
,
Ovl
,
Peak
,
Max
,
Min
for
Sound measurements or
RMS
,
Ovl
,
Peak
,
P
–P
,
MTVV
for Vibration measurements.
6
1
3
7
5
4
8
2
Summary of Contents for SVAN 979
Page 272: ...272 SVAN 979 User Manual Appendixes 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Page 273: ...273 SVAN 979 User Manual Appendixes 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Page 274: ...274 SVAN 979 User Manual Appendixes 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Page 275: ...275 SVAN 979 User Manual Appendixes 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Page 312: ...312 SVAN 979 User Manual Appendixes Summary curve ...
Page 348: ...348 SVAN 979 User Manual Appendixes 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Page 349: ...349 SVAN 979 User Manual Appendixes 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz ...
Page 350: ...350 SVAN 979 User Manual Appendixes 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz ...
Page 351: ...351 SVAN 979 User Manual Appendixes 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz ...
Page 352: ...352 SVAN 979 User Manual Appendixes 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz ...
Page 370: ...370 SVAN 979 User Manual Appendixes O ring gasket locations inside ...