Summary Results saving
The
Summary Results
parameter switches on or off
saving the full set of Summary results that the instrument
measures with the
Integration Period
step:
L
,
Leq
,
LE
,
Lden
,
LEPd
,
Ltm3
,
Ltm5
,
Lnn
,
OVL
,
Lpeak
,
Lmax
,
Lmin
.
►
Note: In the Simple interface mode, the Summary Results parameter is hidden, but the
instrument will use settings previously defined in the Advanced mode or default settings (On)
.
5.5.2 Selection of results for logging
– Logger Results
The
Logger Results
list you can select results for three
independent profiles, which will be logged in the logger
file during measurement with the
Logger Step
.
For the
Lev. Met.
function, it is possible to log next
results: Lpeak
(
Lpk
),
Lmax
,
Lmin
and
Leq
. For other
measurement functions the list of active logger results will
be different.
<ENT>
Activation / deactivation can be done with the
◄
/
►
key
pressed together with
<Shift>
. The position is changed
with the
◄
/
►
or
▲
/
▼
key.
▼
Note: When Logger is switched Off or no results for logging were selected, the logger plot
cannot be activated in Disp. Modes and therefore doesn
’t appear on the display.
Note: In the Simple interface mode, the Logger Results position is hidden, but the
instrument will use settings previously defined in the Advanced mode or default settings (all
results are selected)
.
5.5.3 Logger trigger settings
– Logger Trigger
In the
Logger Trigger
list, you can configure the way the
logger results will be registered in the logger file. It is a
context list in which the trigger can be switched
Off
or On
by selecting its type in the
Trigger
position. When the
trigger is selected, other parameters appear in the list: a
measured result that is checked for a trigger condition
(
Source
), a threshold level (
Level
) as well as a number
of results saved in the logger before the trigger condition
is met (
Pre
) and the number of the results saved in the
logger after the last trigger condition is met during logging
(
Post
).
<ENT>
Note: In the Simple interface mode, the Logger Trigger position is hidden, but the
instrument will use settings previously defined in the Advanced mode or default settings
(Trigger: Off)
.
Trigger disabling
The logger trigger (
Trigger
) can be switched
Off
with the
◄
key. The trigger is
switched on if the
Level +
or
Level
–
mode is selected with the
►
key.
Summary of Contents for SVAN 971
Page 98: ...SVAN 971 User Manual 98 ...
Page 154: ...SVAN 971 User Manual Appendixes 154 1000 Hz 1250 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Page 155: ...SVAN 971 User Manual Appendixes 155 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Page 156: ...SVAN 971 User Manual Appendixes 156 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Page 157: ...SVAN 971 User Manual Appendixes 157 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Page 206: ...SVAN 971 User Manual Appendixes 206 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Page 207: ...SVAN 971 User Manual Appendixes 207 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Page 208: ...SVAN 971 User Manual Appendixes 208 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Page 209: ...SVAN 971 User Manual Appendixes 209 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...