LEQ detector
Following LEQ detectors are available in the instrument:
Imp.
,
Fast
and
Slow
.
Dosimeter
specific parameters can be set in accordance with the OSHA HC
(Occupational Safety and Health Administration - Hearing Conversation),
OSHA PEL (Occupational Safety and Health Administration
– Permissible
Exposure Level) and ACGIH standards.
Criterion Level
is a
steady noise level permitted for a full eight-hour work shift
:
60dB
,
65dB
,
70dB
,
75dB
,
80dB
,
84dB
,
85dB
,
87dB
,
90dB
;
Threshold Level
is a
noise level limit below which the dosimeter does not
accumulate noise dose data
:
None
,
60dB
,
65dB
,
70dB
,
75dB
,
80dB
,
85dB
,
90dB
;
Exchange Rate
is an
amount by which the permitted sound level may increase
if the exposure time is halved
:
2
,
3
,
4
,
5
,
6
;
ULT Threshold Level
(Upper Level Time)
is a threshold level for calculation of
the ULT results:
70dB
÷
140dB
;
PTC Threshold Level
(Peak Threshold Counter) is a threshold level for
calculation of the PTC results:
70dB
÷
140dB
.
11.4 C
HECKING MEASUREMENT RANGE
–
R
ANGE
The measurement range for the
Dosimeter
function is
set to
Normal
and you cannot change it. The detailed
description of the measurement range parameters is
given in Appendix C.
<ENT>
11.5 S
ETTING EXPOSURE TIME
–
E
XPOSURE
T
IME
The
Exp. Time
position enables setting the desired
value of the workday exposure time which is used for
calculation of the
LEPd
results (see Appendix D).
<ENT>
11.6 S
ETTING ALARM THRESHOLDS FOR DOSE METER RESULTS
–
A
LARM
The
Alarm
position is active only in the
Dosimeter
function and enables programming the alarm thresholds
for three profiles (
Thresh. P1 (2,3)
).
Thresholds can be set for next measurement results of
the
Dosimeter
in ranges:
<ENT>
DOSE
: 1÷200%;
D_8h
: 1÷200%;
PTC
: 1÷1000;
ULT
: 1÷60s.
If
Off
is selected, the alarm for the measurement result
is switched off.
<ENT>
Summary of Contents for SV 971A
Page 220: ...SV 971A User Manual Appendixes 220 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 221: ...SV 971A User Manual Appendixes 221 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 222: ...SV 971A User Manual Appendixes 222 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 223: ...SV 971A User Manual Appendixes 223 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 224: ...SV 971A User Manual Appendixes 224 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 232: ...SV 971A User Manual Appendixes 232 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 233: ...SV 971A User Manual Appendixes 233 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 234: ...SV 971A User Manual Appendixes 234 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 235: ...SV 971A User Manual Appendixes 235 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 236: ...SV 971A User Manual Appendixes 236 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 298: ...SV 971A User Manual Appendixes 298 O ring gasket locations inside...