4 CONFIGURING MEASUREMENT PARAMETERS
– Measurement
The
Measurement
section combines elements related
to measurement parameters configuration.
To open the
Measurement
section, press the
<Menu>
key, select the
Measurement
position and press
<Enter>
.
<ENT>
The content of the
Measurement
list depends on the
Interface
mode
(
Simple
and
Advanced
) and
Measurement Function
. Some example screens for
Advanced
and
Simple
modes are presented.
The
Measurement
section contains following positions:
General Set
allowing you to set general measurement parameters;
Meas. Trig.
allowing you to configure the measurement trigger. This position appears only
in the
Advanced
interface mode;
Profiles
allowing you to set parameters specific for the profile. This position disappears
in the
Dosimeter
function;
Profile 1 (2,3)
allowing you to set parameters specific for profiles in the
Dosimeter
function.
These positions appear only in the
Dosimeter
function instead of
Profiles
;
Alarm
allowing you to programme the alarm function. This position appears only in the
Dosimeter
function and the
Advanced
interface mode;
Logging
allowing you to configure the logging function;
Spectrum
allowing you to set spectrum parameters. This position becomes available only
in the 1/1- and 1/3-octave analysis functions;
Range
allowing you to set the required measurement range;
Comp. Filter
allowing you to switch on the required compensation filter. This position appears
only in the
Advanced
interface mode;
Stat. Lev.
allowing you to define 10 statistical levels;
Exp. Time
allowing you to set the exposure time for dose measurements. This position
appears only in the
Dosimeter
function and
Advanced
interface mode;
Timer
allowing you to programme the internal timer. This position appears only in the
Advanced
interface mode.
4.1 S
ETTING GENERAL MEASUREMENT PARAMETERS
–
G
ENERAL
S
ETTINGS
The
General Set
screen allows to programme general
measurement parameters: delay of the measurement
start of (
Start Delay
), synchronisation with the
instrument’s RTC (
Start Sync.
), integration period/
measurement run time (
Integr. Per
), repetition of
measurement cycles (
Rep. Cycles
), LEQ detector type
(
LEQ Integr.
)
and
duration
of
day
periods
(
Day Time L.
).
<ENT>
Summary of Contents for SV 971A
Page 220: ...SV 971A User Manual Appendixes 220 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 221: ...SV 971A User Manual Appendixes 221 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 222: ...SV 971A User Manual Appendixes 222 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 223: ...SV 971A User Manual Appendixes 223 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 224: ...SV 971A User Manual Appendixes 224 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 232: ...SV 971A User Manual Appendixes 232 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 233: ...SV 971A User Manual Appendixes 233 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 234: ...SV 971A User Manual Appendixes 234 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 235: ...SV 971A User Manual Appendixes 235 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 236: ...SV 971A User Manual Appendixes 236 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 298: ...SV 971A User Manual Appendixes 298 O ring gasket locations inside...