66
SV
104BIS User Manual
Figure 6-19
Keyboard security settings panel
To turn on the security option: switch on
“Lock During Measurement”
. SV 104BIS will disable the keyboard
every time, the measurement run is started.
how to lock and unlock the SV 104BIS instrument.
If
“Unlock on Key”
is set to
On
, SV 104BIS will require special code to be input by pressing four keys defined
in this panel in a particular sequence
If
“Unlock on Key”
is set to
Off
, SV 104BIS can be locked/unlocked without providing Lock/Unlock sequence.
Simply hold the
key for a couple of seconds during which a countdown (
“Keyboard lock/unlock” 3…
2… 1…
) is displayed and the unit
gives you time to decide if you really want to activate/deactivate the security
lock. If you release the key too early, the operation will be cancelled.
6.3.9.4
Auxiliary settings
Under auxiliary settings panel it is possible to:
•
Enable additional warning screens to be displayed under certain conditions:
o
“Logging disabled”
it warns the operator that time history results will not be stored
o
“Power off”
additional confirmation just before switching off.
•
“Comment file name”
defines the name of the Voice note comment file. “
Comment Text”
is also
able to be entered here if required.
•
“Vibration Marker”
is used on the basis of acceleration threshold setting (
Off, 1g,…15g
) the lower
the threshold level selected then the more sensitive the dosimeter will be to possible bumps and
shocks during use.
•
“Language”
enables the user to change the menu language displayed on the screen of the
dosimeter. The default language is English.
•
“Time
To Automatic
Shutdown”
enables the user to change time period after which the unit will be
shut down if no key will be pressed.
•
“Bluetooth”
enables the user to switch on or off the Bluetooth
®
connection.
•
“
Bluetooth PIN
”
code
configuration is required to establish connection
.
Note:
For Air-transport
Bluetooth
®
interface should be
turned off
. Make sure that correct settings
file is applied
.
Summary of Contents for SV 104BIS
Page 139: ...139 SV104BIS User Manual 250 Hz 315 Hz 400 Hz 500 Hz...
Page 140: ...140 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Page 141: ...141 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 142: ...142 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Page 143: ...143 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Page 144: ...144 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 148: ...148 SV104BIS User Manual Figure C 4 Total directional characteristics asymmetrical axis...
Page 150: ...150 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Page 151: ...151 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 152: ...152 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Page 153: ...153 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Page 154: ...154 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 166: ...166 SV104BIS User Manual 1 3 octave filters for 16 0 Hz 1 1 octave filter...
Page 180: ...180 SV104BIS User Manual...