ELECTRICAL SYSTEM 6-21
OIL LEVEL INDICATOR SWITCH
INSPECTION
Measure the continuity between the lead wires of the oil level
indicator switch.
If there is no continuity between the terminals when the float
1
is in the low-level position, replace the oil level indicator switch.
#
09900-25008: Multi circuit tester set
,
Tester knob indication: Continuity test (
-
)
THERMOELEMENT AND CARBURETOR HEATER
INSPECTION
THERMOELEMENT
• Remove the trunk. (
!
5-6)
• Disconnect the thermoelement coupler
1
.
• Connect the thermoelement
2
lead wires to a 12 V battery.
Wait five minutes and feel the thermoelement to see if it has
reached approximately 36°C. If the appropriate temperature is
not reached, replace the thermoelement with a new one.
NOTE:
This check should be carried out when the carburetor is cold.
B/W
R
: Red
Y
: Yellow
B/W : Black with White tracer
W/R : White with Red tracer
Y/W : Yellow with White tracer
Y/W
B/W
Y/W
W/R
R
Y/W
B/W
Y/W
W/R
W/R
Y/W
Y/W
Y
Y/W
Y/W
Y
Thermo-
element
Regulator/
rectifier
Generator
Carburetur
thermo switch
Carburetor
heater