ELECTRICAL SYSTEM 6-13
• Apply a small quantity of SUZUKI MOLY PASTE to the arma-
ture shaft.
/
/
/
/
/
99000-25140: SUZUKI MOLY PASTE
• Apply SUZUKI SUPER GREASE “A” to the O-ring.
.
.
.
.
.
99000-25010: SUZUKI SUPER GREASE “A”
STARTER RELAY INSPECTION
• Remove the leg shield cover/rear leg shield. (
!
5-9)
• Remove the starter relay.
Apply 12 volts to terminals
A
and
B
, and measure for continuity
between terminals
C
and
D
as shown. If the starter relay clicks
and continuity is found, the relay is operating correctly.
#
09900-25008: Multi circuit tester set
,
Tester knob indication: Continuity test (
-
)
• Disconnect the starter relay coupler.
Measure the starter relay resistance between the terminals. If
the resistance is out of specification, replace the starter relay
with a new one.
#
09900-25008: Multi circuit tester set
)
Tester knob indication: Resistance (
Ω
Ω
Ω
Ω
Ω
)
&
Starter relay resistance
Standard: 80 – 120
Ω
Ω
Ω
Ω
Ω