ELECTRICAL SYSTEM 6-3
BATTERY
• The MF battery used in this motorcycle does not require main-
tenance (e.g., electrolyte level inspection, distilled water re-
plenishing).
• During normal charging, no hydrogen gas is produced. How-
ever, if the battery is overcharged, hydrogen gas may be pro-
duced. Therefore, be sure that there are no fire or spark sources
nearby (e.g., short-circuit) when charging the battery.
• Be sure to recharge the battery in a well-ventilated and open
area.
• Note that the charging system for the MF battery is different
from that of a conventional battery. Do not replace the MF bat-
tery with a conventional battery.
CONNECTING THE BATTERY
• When disconnecting terminals from the battery for disassem-
bly or servicing, be sure to disconnect the
-
battery lead wire,
first.
• When connecting the battery lead wires, be sure to connect
the
+
battery lead wire, first.
• If the terminal is corroded, remove the battery, pour warm water
over it and clean it using a wire brush.
• After connecting the battery, apply a light coat of grease to the
battery terminals.
• Reinstall the cover over the
+
battery terminal.
USING THE MULTI CIRCUIT TESTER
• Properly use the multi circuit tester
+
and
-
probes. Improper
use can cause damage to the motorcycle and tester.
• If the voltage and current values are not known, begin mea-
suring in the highest range.
• When measuring the resistance, make sure no voltage is ap-
plied. If voltage is applied, the tester will be damaged.
• After using the tester, turn the switch to the OFF position.
"
Before using the multi circuit tester, read its instruction
manual.
WIRING PROCEDURE
• Properly route the wire harness according to “WIRE, CABLE
AND HOSE ROUTING”. (
!
7-9 to -15)