Set-up
Technical Handbook
019722-101 Rev. 05
32
SC-350/360
>>>
Note!
A normal start, without counting any coins, adds 2 to the register
(1 start + 1 reversal).
Total number of coins counted by the machine:
Press and hold
ACC
. The display shows “C o i n” and then the
number of coins counted since the last time the value was reset.
Total number of solenoid brakings:
Press and hold
B
. The display shows “S o I” and then the
number of solenoid brakings since the last time the value was
reset.
Reset:
To reset any of the above statistics, press
C
when the display is
showing the statistical value.
Example:
To zero the total number of solenoid brakings:
a) Press and hold
B
.
b) When the display shows the number of solenoid brakings, press
and hold
C
while continuing to press
B
.
c) When the display changes to show “0”, release
B
and
C
. The total
number of solenoid brakings is zeroed.
• Press
Start/Stop
. The machine is no longer in the statistics mode
and is ready for normal operation.
7.12 Service Intervals
Note!
This function is available in program version 3.05 and on.
When the machine is due for servicing the decimal point to the far
left of the display flashes. It is possible to continue using the
machine.
To enable/disable the servicing function:
a) Press and hold
Q
and
B
while switching
On
the machine.
b) The display shows “S E r” to indicate that the service interval
information is accessible.
>>>