EMERGENCY STOP
When the emergency stop button is pressed there is a text appearing on
the touch screen with an instruction to reset the machine by either
pressing the reset button or by clicking on the message on the screen.
ALARM INDICATOR
The Alarm Indicator has the following
indications:
Flashing red when there is any active,
unacknowledged alarm.
Flashing green when no active alarms
exist, but inactive unacknowledged
alarms exist.
Flashing green when there are only active acknowledged alarms.
10.4.1
ALARM LOG
Alarms must be acknowledged using this menu.
Alarm is active. The source of the
alarm remains (i.e. fuse is blown)
and alarm is not acknowledged in
the alarm log menu.
Alarm is inactive. The source of the
alarm is solved (i.e. fuse is reset)
but the alarm is not acknowledged
in the alarm log menu.
Alarm is acknowledged. The
source of the alarm remains (i.e.
fuse is blown) but alarm is
acknowledged in the alarm log.
Alarm is normal. The source of the
alarm is solved (i.e. fuse is reset)
and the alarm is acknowledged in
the alarm log menu.