Setting
©
2004-2010 Sure Electronics Inc.
ME-PC11121_Ver1.0_Page 7
2.4 Working Mode Setting
TABLE 2-6 WORKING MODE SETTING
Working
Mode
Condition
Status
Operation
MOD0
No external
devices (the
relay not used)
-
No other operations are needed after the
panel is powered. Press “ON/OFF” key to
turn on or off the display.
MOD1
External
heating devices
Single
threshold
SET
→
+/-(upper limit setting)
→
SET
→
SET
→
SET
→
SET
→
+(mode1)
→
OK
MOD2
External
cooling devices
Single
threshold
SET
→
+/-(upper limit setting)
→
SET
→
SET
→
SET
→
SET
→
+
→
+(mode2)
→
OK
MOD3
External
heating devices
Hysteresis
control
SET
→
+/-(upper limit setting)
→
SET
→
+/-(lower limit setting)
→
SET
→
SET
→
SET
→
+
→
+
→
+(mode3)
→
OK
MOD4
External
cooling devices
Hysteresis
control
SET
→
+/-(upper limit setting)
→
SET
→
+/-(lower limit setting)
→
SET
→
SET
→
SET
→
+
→
+
→
+
→
+(mode4)
—>
OK
MOD5
External
devices need to
be opened at a
specific time
Time relay
SET
→
SET
→
SET
→
SET
→
+/-(time setting)
→
SET
→
-
→
-(mode5)
→
OK
MOD6
External
devices need to
be closed at a
specific time
Time relay
SET
→
SET
→
SET
→
SET
→
+/-(time setting)
→
SET
→
- (mode6)
→
OK
Note:
℃
/
℉
setting:
SET
→
SET
→
SET
→
+/-
→
OK
.