ioEntry Smart/Pass BioEntry Installation Guide 10
Copyright © 2005 by Suprema Inc. http://www.supremainc.com
2.
Installing BioEntry™
2.1.
Connecting wires
The BioEntry is connected to other devices of the security system through the
pigtail cable at the rear side.
See
Table 1 for wire colors and signals.
Wire color
Signal
Description
Shield (naked wire)
EARTH
GND
Ground Earth
Blue with yellow tracer
Reserved
Black with white tracer
IN0
TTL IN 0
Black
IN1
TTL IN 1
Brown with white tracer
OUT0
TTL OUT 0
Brown
OUT1
TTL OUT 1
Red with white tracer
IO_GND
GND, for IO signals
Red
Reserved
Orange with white tracer
WO_GND
Wiegand Output, GND
Orange
WO_VREF
Wiegand Output, VREF
Yellow with red tracer
WO_D0
Wiegand Output, Data 0
Yellow
WO_D1
Wiegand Output, Data 1
Dark Green with white tracer
WI_D0
Wiegand Input, Data 0
Dark Green
WI_D1
Wiegand Input, Data 1
Blue with white tracer
COM_GND
Comm. GND (for RS-232C)
Blue
WI_GND
Wiegand Input GND
Violet with white tracer
RX2
Receive data, RS-232C level
Violet
TX2
Transmit data, RS-232C level
Gray with red tracer
RX+
RX+, RS-485 level
Gray
RX-
RX-, RS-485 level
White with red tracer
TX+
TX+, RS-485 level
White
TX-
TX-, RS-485 level
Green with yellow tracer
POW_GND
Power GND
Red with yellow tracer
POW+
Power Input