16
5.1.3 Installation of Position Sensor
Position sensor includes two modules:
Proximity Switch Module: Main Mounting Plate with a chute for length adjustment,
Sub-mounting Plate with a chute for angle adjustment, Upper Proximity Switch and Lower
Proximity Switch [Detecting Distance: 1~8mm].
Magnet Module: Thread Pole
, Weld-nut, Tight-nut, Nylon Block, Magnet Block.
1: Lift-arm Seat; 2: Lift-arm; 3: Main Mounting Plate; 4: Sub-mounting Plate; 5: Weld-nut;
6: Thread Pole; 7:
Nylon Block; 8: Fastening Nut for Position Ajustment;
9:
Magnet Block;
10:
Upper
Proximity Switch;
11:
Upper Proximity Switch; 12: Fastening Nut for Length Ajustment;
13:
Fastening
Nut for Angle Ajustment.
Sensing Distance Adjustment: Adjust the sensing distance between the Magnet Block and the
Proximity Switch to 3~5mm.
Suggestion: Install the position sensor on the lift-arm seat and lift-arm which are at the same side that
the weighing indicator installed on.
2
1
9
6
10
11
12
5
3
4
7
13
8