2. By using the arrow keys or the menu «CLEAR AVERAGE» is selected.
3. Accept this choice by pressing the ON/TEST button. An “OK” will appear in the display followed by

automatic return to the menu «MEASURE».

How to turn off the device

Press the ESC/OFF button and hold it down until the unit is turned off. Or the unit will
automatically turn off if 45 seconds have passed since use of any button.

Battery

The unit comes with a 9 volt Alkaline battery which are placed in the shock proof transport suitcase
carrying the unit. The battery is to be placed in the compartment situated in the lower half of the units when
it is turned around.
When the battery is in need of a replacement the message “Change battery” will appear in the display.

Only

use 9 volt Alkaline batteries

. To check the level of the battery in use select the menu «BATTERY».

-

4 bars indicates full battery condition

-

1 bar indicates low battery condition.

It is advised to have an additional battery close at hand when 1 bar indicates the level of the battery.

How to make your own grain scale

If you desire to make a scale for a particular crop not incorporated in the factory unit, then this can be done
by selecting the scale with the name “Bit” and follow the below mentioned instructions:

1. Turn off the unit by pressing the ON/TEST button. The menu «MEASURE» (choice of crop) will

automatically appear on the display.

2. Accept the choice of menu by pressing the ON/TEST button.
3. By using the arrow keys or the scale “Bit” is selected.
4. Fill the test cell with the desired crop and known moisture content, screw the lid on and perform the

test as described earlier.

5. Note the value which appears in the display together with the moisture content in the crop.

Perform this process repeatedly using different levels of moisture content until the scale meet the
range and requirements needed.

Storage/Use

It is recommended that you store the instrument in the enclosed transport packaging, that the instrument is
not exposed to large temperature fluctuations and that it is kept free of moisture.
If the instrument is taken into a warmer environment from a cold storage location, it is recommended that
one allow the unit to acclimatise in order that condensation does not affect the result of the measurement.
At the end of the season, wipe all surfaces with a well-wrung damp cloth and remove the battery from the
unit.

Ver 1.1.0

Page 10/12

Summary of Contents for SUPERPOINT

Page 1: ...uperpoint User Manual Instruction manual Bedienungsanleitung Notice d utilisation Manuale di Istruzioni Gebruiksaanwijzing Bruksanvisning Instrucciones de uso Instrukcja obs ugi Ver 1 1 0 GB Page 1 12...

Page 2: ...ting the Calibration of the Meter 8 Superpoint Settings and Menu s 9 MEASURE 9 BATTERY 9 CLEAR AVERAGE 9 CALIBRATION 9 Some more valuable information about the moisture meter 9 How to clear the calcul...

Page 3: ...complies with EU Directives and standards among other regulations for electrical safety and electromagnetic compatibility Inaccurate usage or handling may however result in damage to the product and...

Page 4: ...ckproof carrying case 2 year guarantee Introduction Thank you for choosing Supertech s Superpoint Grain Moisture Analyser This moisture meter is a new generation of digital moisture meters that operat...

Page 5: ...moisture analyser Compressor lid 9V Battery Operator s manual Shockproof carrying case Part Locator 1 Compression lid 2 Compression housing lower compression cell 3 Display 4 Superpoint grip 5 Keypad...

Page 6: ...choice of crop will automatically appear in the display Select the crop to be tested by using the arrow keys or To select a different crop press the ESC OFF button to return to MEASURE and use arrow k...

Page 7: ...esult if the test button is not pressed immediately after screwing on the lid Due to different sized kernels one can expect slight deviations in the measurements since each sample will not be packed t...

Page 8: ...N TEST button The menu MEASURE choice of crop will automatically appear on the display 2 Using the arrow keys or the menu CALIBRATION is selected 3 Accept this menu by pressing the ON TEST button 4 By...

Page 9: ...EASURE is used to choose the crop to be tested BATTERY This menu will give you an overview of the battery level CLEAR AVERAGE This menu is used to clear the average of the average of the last five mea...

Page 10: ...r crop not incorporated in the factory unit then this can be done by selecting the scale with the name Bit and follow the below mentioned instructions 1 Turn off the unit by pressing the ON TEST butto...

Page 11: ...erature compensation Automatic Weight including case 1 6 kg Dimension 13x21x8 cm Battery 9 V Alkaline Display 2 line LCD with backlight Accuracy Better than 0 5 in normal moisture range by using avera...

Page 12: ...n Failing to meet this requirement can result in heavy metals accumulating in the environment and potentially be damaging towards humans animals and natural resources EU Declaration of Conformity Acco...