and moisture contents can now be read off the y-axis for any Bit value measured using subsequent
samples of the same crop in the meter.
Quick Guide to Display Messages
Symbol:
Definition:
*
Calibration has been adjusted from the factory setting for the crop being displayed.
Tempe+
Grain temperature is above the upper operating limit (50°C).
Temperature --
Grain temperature is below the lower operating limit (0°C).
Hi
Grain moisture content is above the upper limit (varies with crop).
Lo
Grain moisture content is below the lower limit (varies with crop).
Change battery
Battery needs replacing.
Technical Specifications
●
Measuring range
(Moisture): 5 to 50% Depending on crop type
●
Operating range
(Temperature): 0 to 50 ºC
●
Resolution
: 0.1% moisture
●
Temperature compensation
: Automatic
●
Weight including case
: 2 kg
●
Dimension
: 13 x 21 x 8 cm
●
Battery:
9 V Alkaline
●
Display
: 2 line LCD with backlight
●
Accuracy
: Better than +/- 0.25% in normal moisture range, by using average and
calibration adjustments
Troubleshooting
➢
The meter does not turn on by pressing the ON/TEST button
Change the battery. It is a good idea to always have a new battery in your carrying-case
➢
The meter shows Lo<xx% in the display
The moisture content of the sample in the measuring cell is below the measuring range
➢
The meter shows Hi>xx% in the display
The moisture content of the sample in the measuring cell is over the measuring range
Or
Ver 1.1.0
GB