8
EN
i
5. Technical Specifications
Technical specifcations
Supply voltage:
230 V ~ / 50 Hz
Nominal power:
approx. 70 W
Consumption:
Standby: approx. 1 W
Nominal torque:
approx. 8 Nm
Maximum tractive force:
30 Kg
Transient operation (KB):
4 minutes
(maximum running time)
Overrun:
< 0.4 Revolutions
Protection class:
II (only for use in dry rooms)
Number of switching times: 2 (up and down)
Max. shutter surface area:
(plastic roller shutters)
5 m
2
Permissible ambient
temperature:
approx. 40 °C
Automatic solar function
setting range
2,000 to 20,000 Lux
Sound pressure
level (LpA):
≤ 70 dB(A)
Power failure
The automatic LED flashes in the event of a power
failure.
The automatic LED lights up permanently again after
pressing the UP (
▲
) or DOWN (
t
) button.
Data retention subsequently to power failure
The configured switching times are retained after a
power failure. As soon as the power supply is restored,
the opening and closing times will be executed again.
However, the times will be offset by the duration of the
power failure.
Example:
◆
Power failure from 19:30 - 19:45 hours.
◆
The closing time was previously set to 19:30 hours.
◆
The roller shutters will close at 19:45 hours due to
the duration of the power failure.
Summary of Contents for GW70