Chapter 3: System Interface
3-3
3-3 Control Panel LEDs
The control panel located on the front of the SC815TQ-R700WB/600WB chassis
has fi ve LEDs. These LEDs provide you with critical information related to different
parts of the system. This section explains what each LED indicates when illuminated
and any corrective action you may need to take.
NIC2
Indicates network activity on LAN2 when fl ashing.
Information LED
See the following table for the status shown by this LED.
Information LED
Status
Description
Continously on and red
An overheat ocondition has occured. (This may be caused by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative power supply.
Solid blue
Local UID has been activated. Use this function to locate the server in a rack
environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this function to locate the server from a
remote location.
NIC1
Indicates network activity on LAN1 when fl ashing.
HDD
Indicates IDE channel activity when fl ashing.