SuperStorage SSG-1129P-ACR10N4L User's Manual
52
Hot-Swap for NVMe Drives
Supermicro Ultra servers support NVMe surprise hot-swap. For even better data security,
NVMe
orderly
hot-swap is recommended. NVMe drives can be ejected and replaced remotely
using IPMI.
Note
: If you are using VROC, see the VROC appendix in this manual instead.
Ejecting a Drive
1.
IPMI > Server Health > NVMe SSD
2. Select Device, Group and Slot, and click
Eject
.
After ejecting, the drive Status LED
indicator turns green.
3. Remove the drive.
Note that
Device
and
Group
are categorized by the CPLD design architecture. The
SSG-1129P-ACR10N4L server has one Device and one Group.
Slot
is the slot number on which the NVMe drives are mounted.
Replacing the Drive
1. Insert the replacement drive.
2.
IPMI > Server Health > NVMe SSD
3. Select Device, Group and slot and click
Insert
. The drive Status LED indicator flashes
red, then turns off. The Activity LED turns blue.
Figure 3-12. IPMI Screenshot