SuperServer 2049U-TR4 User's Manual
32
Installing the Processor Heatsink Module
After assembling the Processor Heatsink Module (PHM), install the PHM onto the CPU socket:
1. Align hole 1 of the heatsink with the printed triangle on the CPU socket. See the left
image below.
2. Make sure all four holes of the heatsink are aligned with the socket before gently placing
the heatsink on top.
3. With a T30 Torx-bit screwdriver, gradually tighten screws #1 - #4 to assure even
pressure. The order of the screws is shown on the label on top of the heatsink. To
avoid damaging the processor or socket, do not use a force greater than 12 lbf-in when
tightening the screws.
4. Examine all corners to ensure that the PHM is firmly attached to the socket.
#1
#2
#3
#4
Small Guide Post
Large Guide Post
Oval D
T30 Torx Screwdriver
Use a torque
of 12 lbf-in
Oval C
Printed Triangle
Mounting the Processor Heatsink Module
onto the CPU socket (on the motherboard)
Tighten the screws in
the sequence of 1, 2, 3, 4