5-13
Chapter 5: BIOS
Parameter
Selector
This static display shows the parameter of your MAC Address configuration.
MAC Address
The BIOS will automatically enter the MAC address of your system; however it
may be over-ridden. MAC addresses are 6 two-digit hexadecimal numbers (base
16, 0~9, A, B, C, D, E and F) separated by dots (such as 00.30.48.D0.D4.60).
Current MAC
Address in
BMC
This static display shows the current MAC address used for your IPMI
connection.
Subnet Mask
Subnet masks tell the network which subnet this system belongs. The value of
each three-digit number separated by dots should not exceed 255.
Parameter
Selector
This static display shows the parameter of your Subnet Masks configuration.
Subnet Mask
This static display shows the current Subnet Mask setting for your IPMI
connection.
Current Subnet
Mask in BMC
This static display shows the current Subnet Mask used for your IPMI
connection.
Gateway
Address
Enter the Gateway address for your system using this sub-menu. This should be
in decimal and dotted quad form (such as 192.168.10.253). The value of each
three-digit number separated by dots should not exceed 255.
Parameter
Selector
This static display shows the parameter of your Gateway Address configuration.
Gateway
Address
The BIOS will automatically enter the Gateway address of your system; however
it may be over-ridden. MAC addresses are 6 two-digit hexadecimal numbers
(base 16, 0~9, A, B, C, D, E and F) separated by dots (such as
00.30.48.D0.D4.60).
Current IP
Address in
BMC
This static display shows the current Gateway address used for your IPMI
connection.
Table 5-12. Remote Access Configuration Sub-menu
Menu Option
Description
Remote Access
This option allows you to select your remote access type. Options include COM1
and
COM2
.
Serial Port Number
This option allows you to select a serial port for console redirection if the
selected port is enabled. Options include COM1 and
COM2
.
The Base Address IRQ is displayed statically under this option for your
reference.
Serial Port Mode
Use this option to select the serial port mode setting. Options include
115200
8,n,1
/ 57600 8,n,1 / 38400 8,n,1 / 19200 8,n,1 / 09600 8,n,1
Flow Control
This option allows you to select Flow Control for redirection. Options include
None
, H
ARDWARE
or S
OFTWARE
.
Table 5-11. IPMI Configuration Sub-menu (Continued)
Menu Option
Description
Summary of Contents for SBI-7426T-SH
Page 1: ...SBI 7426T SH Blade Module User s Manual Revison 1 0a ...
Page 4: ...SBI 7426T SH Blade Module User s Manual iv Notes ...
Page 8: ...SBI 7426T SH Blade Module User s Manual viii Notes ...
Page 10: ...SBI 7426T SH Blade Module User s Manual x Notes ...
Page 16: ...SBI 7426T SH Blade Module User s Manual 1 6 Notes ...
Page 34: ...SBI 7426T SH Blade Module User s Manual 3 16 Notes ...
Page 68: ...SBI 7426T SH Blade Module User s Manual A 10 Notes ...
Page 70: ...SBI 7426T SH Blade Module User s Manual 0 2 Notes ...