SBI-7126TG Blade Module User’s Manual
5-14
Current IP
Address in
BMC
This static display shows the current IP address used for your IPMI connection.
Subnet Mask
Subnet masks tell the network which subnet this system belongs. The value of
each three-digit number separated by dots should not exceed 255.
Parameter
Selector
This static display shows the parameter of your Subnet Masks configuration.
Subnet Mask
This static display shows the current Subnet Mask setting for your IPMI
connection.
Current Subnet
Mask in BMC
This static display shows the current Subnet Mask used for your IPMI
connection.
Gateway
Address
Enter the Gateway address for your system using this sub-menu. This should be
in decimal and dotted quad form (such as 192.168.10.253). The value of each
three-digit number separated by dots should not exceed 255.
Parameter
Selector
This static display shows the parameter of your Gateway Address configuration.
Gateway
Address
The BIOS will automatically enter the Gateway address of your system; however
it may be over-ridden. MAC addresses are 6 two-digit hexadecimal numbers
(base 16, 0~9, A, B, C, D, E and F) separated by dots (such as
00.30.48.D0.D4.60).
Current IP
Address in
BMC
This static display shows the current Gateway address used for your IPMI
connection.
MAC Address
Enter the MAC address for your system using this sub-menu. This should be in
decimal and dotted quad form (such as 192.168.10.253). The value of each
three-digit number separated by dots should not exceed 255.
Parameter
Selector
This static display shows the parameter of your MAC Address configuration.
MAC Address
The BIOS will automatically enter the MAC address of your system; however it
may be over-ridden. MAC addresses are 6 two-digit hexadecimal numbers (base
16, 0~9, A, B, C, D, E and F) separated by dots (such as 00.30.48.D0.D4.60).
Current MAC
Address in
BMC
This static display shows the current MAC address used for your IPMI
connection.
BMC Watch Dog
Timer Action
This setting allows the BMC to reset or power down the system if the operating
system crashes or hangs. Options include
Disabled
, Reset System, Power
Down or Power Cycle.
Table 5-13. Event Log Configuration Sub-menu
Menu Option
Description
View Event Log
This setting allows you to view all unread events on the Event Log.
Mark All Events as
Read
This setting marks all events as read. Options are OK and
Cancel
when
selected.
Table 5-12. IPMI Configuration Sub-menu (Continued)
Menu Option
Description
Summary of Contents for SBI-7126TG
Page 1: ...SBI 7126TG Blade Module User s Manual Revison 1 0a...
Page 4: ...SBI 7126TG Blade Module User s Manual iv Notes...
Page 8: ...SBI 7126TG Blade Module User s Manual 2 Notes...
Page 10: ...SBI 7126TG Blade Module User s Manual 2 Notes...
Page 16: ...SBI 7126TG Blade Module User s Manual 1 6 Notes...
Page 34: ...SBI 7126TG Blade Module User s Manual 3 16 Notes...
Page 68: ...SBI 7126TG Blade Module User s Manual A 10 Notes...
Page 70: ...SBI 7126TG Blade Module User s Manual 0 2 Notes...