background image

6U/3U MicroBlade

Network System Options

User’s Manual

Revison 1.0d

MBM-GEM-001 2.5-Gbps/1 Gbps 

Ethernet Switch Module

MBM-XEM-001 10 Gbps

Ethernet Switch Module

MBM-XEM-002 10 Gbps

Ethernet Switch Module

MBM-GEM-004 1 Gbps

Ethernet Switch Module

Summary of Contents for MicroBlade MBM-GEM-001

Page 1: ...k System Options User s Manual Revison 1 0d MBM GEM 001 2 5 Gbps 1 Gbps Ethernet Switch Module MBM XEM 001 10 Gbps Ethernet Switch Module MBM XEM 002 10 Gbps Ethernet Switch Module MBM GEM 004 1 Gbps...

Page 2: ...enue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found...

Page 3: ...vides an overview of this manual Chapter 2 System Safety You should familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and serv...

Page 4: ...6U 3U MicroBlade Network System Options User s Manual iv Notes...

Page 5: ...isposal 2 14 Hot Swap Fan Warning 2 15 Gevaarlijk bewegende onderdelen Houd voldoende afstand tot de bewegende ventilatorbladen Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van...

Page 6: ...igabit Ethernet Switch Module 4 3 LED Indicators 4 4 Ports 4 4 4 3 MBM XEM 001 10 Gigabit Ethernet Switch Module 4 5 LED Indicators 4 6 Ports 4 6 4 4 MBM XEM 002 10 Gigabit Ethernet Switch Module 4 7...

Page 7: ...itch Module 3 4 Figure 3 4 Blade Status Screen 3 5 Figure 3 5 Blade System Screen 3 6 Figure 3 6 Switch Panel 3 6 Figure 4 1 MBM GEM 001 Gigabit Ethernet Switch Module 4 1 Figure 4 2 MBM GEM 004 Gigab...

Page 8: ...6U 3U MicroBlade Network System Options User s Manual viii Notes...

Page 9: ...abit Ethernet Switch Module Ports 4 4 Table 4 7 MBM XEM 001 10 Gigabit Ethernet Switch Module Interface 4 5 Table 4 8 MBM XEM 001 10 Gigabit Ethernet Switch Module Features 4 6 Table 4 9 MBM XEM 001 A...

Page 10: ...6U 3U MicroBlade Network System Options User s Manual x Notes...

Page 11: ...MicroBlade www supermicro com products MicroBlade Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server...

Page 12: ...Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Website www supermicro nl Email sales supermicro nl General...

Page 13: ...ed technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These warnings may also be fou...

Page 14: ...equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a enc...

Page 15: ...t u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE IN...

Page 16: ...tion for short circuit overcurrent protection Ensure that the protective device is rated not greater than 250 V 20 A 250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im G...

Page 17: ...250 V 20 A 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is...

Page 18: ...o quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les...

Page 19: ...ng sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommand de co...

Page 20: ...n Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci...

Page 21: ...Battery Handling Warning There is the danger of explosion if the battery is replaced incorrectly Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of us...

Page 22: ...lazar la bater a exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las bater as gastadas seg n las instrucciones del fabricante Waarschuwing Er is ontploffingsge...

Page 23: ...ra fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer...

Page 24: ...as System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trase...

Page 25: ...ly with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards...

Page 26: ...andled according to all national laws and regulations Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de es...

Page 27: ...n sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnungen des L ftergeh uses entfernt Advertencia Riesgo de pieza...

Page 28: ...ndere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing Power Cable and AC Adapter Warning When installing the product use the provided or designated connection cables power cables an...

Page 29: ...dos los cables y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el u...

Page 30: ...egeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbie...

Page 31: ...t are common to all switches 3 1 Installing Removing a Switch Module Follow the procedures below for installing or uninstalling a switch module into a MicroBlade system Installing a Switch Module 1 Ma...

Page 32: ...6U 3U MicroBlade Network System Options User s Manual 3 2 Figure 3 1 Installing a Switch Module...

Page 33: ...o verify it is working properly If there are no problems the blue Init OK LED on the module will illuminate and you will see an OK under INITIATED in the SWITCH screen of the management software utili...

Page 34: ...grity 3 2 Configuring the Switch Module Figure 3 3 Configuring the Switch Module A Gigabit Ethernet switch module can be configured using two methods as shown in Figure 3 3 You may configure it Throug...

Page 35: ...stem Logging In to the IPMI 1 Connect a PC to a network that is accessible to the switch For example connect a PC to any of the front panel ports of the switch and make sure the PC has an IP address o...

Page 36: ...in Figure 3 4 and Figure 3 5 is then displayed Figure 3 5 Blade System Screen 3 Clicking on a switch module will display the module in the SWITCH panel on the screen Figure 3 6 You may make changes i...

Page 37: ...thin the program NOTE If two switches are installed in a MicroBlade system you will have to change the IP address of one from the default so that both switches have unique addresses Table 3 1 MBM GEM...

Page 38: ...s Switch A1 has its ports electrically routed to the first network interfaces of the blade servers while the switch designed as Switch A2 has its ports electrically routed to the second network interf...

Page 39: ...1 2 5 Gb s downlink ports for the MicroBlade s LAN interfaces This module has two internal Ethernet paths to the CMM s The switch is used to provide a connection between the Ethernet controller integr...

Page 40: ...442 Gbps non blocking Trunking Link aggregation support Jumbo Frame Support Up to 9kb Remote Management Browser based management Protocols Spanning Tree Rapid Spanning Tree Multiple Spanning Tree 802...

Page 41: ...ion between the Ethernet controller integrated on the mainboard and an external Ethernet device This module is a hot pluggable See Figure 4 2 Table 4 4 and Table 4 5 for switch details Figure 4 2 MBM...

Page 42: ...our 10 Gbps SFP uplink ports and eight 1 Gbps RJ45 ports Bandwidth 88 Gbps non blocking Trunking Link aggregation support Jumbo Frame Support Up to 9kb Remote Management Browser based management Proto...

Page 43: ...ntroller integrated on the mainboard and an external Ethernet device This module is a hot pluggable module See Figure 4 3 Table 4 7 and Table 4 8 for switch details Figure 4 3 MBM XEM 001 10 Gigabit E...

Page 44: ...ports External Four 40Gbps QSFP Bandwidth 960 Gbps non blocking Trunking Link aggregation support Jumbo Frame Support Up to 9kb Remote Management Browser based management Protocols Spanning Tree Rapid...

Page 45: ...en the Ethernet controller integrated on the mainboard and an external Ethernet device This module is a hot pluggable module See Figure 4 4 Table 4 10 and Table 4 11 for switch details Figure 4 4 MBM...

Page 46: ...ps SFP ports Bandwidth 960 Gbps non blocking Trunking Link aggregation support Jumbo Frame Support Up to 9kb Remote Management Browser based management Protocols Spanning Tree Rapid Spanning Tree Mult...

Page 47: ...bE switch module is operational and has passed the POST Power On Self Test with no critical faults Module Fault LED Red Steady On When lit this LED indicates that the MBM GEM 001 GbE switch module has...

Page 48: ...d Steady On When lit this LED indicates that the MBM GEM 004 GbE switch module has either failed the POST or has detected an operational fault within the module When this LED is lit the fault LED on t...

Page 49: ...is LED indicates that the MBM XEM 001 switch module has either failed the POST or has detected an operational fault within the module When this LED is lit the fault LED on the blade enclosure will als...

Page 50: ...D Red Steady On When lit this LED indicates that the MBM XEM 002 switch module has either failed the POST or has detected an operational fault within the module When this LED is lit the fault LED on t...

Page 51: ...ected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such...

Page 52: ...6U 3U MicroBlade Network System Options User s Manual B 2...

Reviews: