12
H12SSW-iNR/NTR User's Manual
Quick Reference Table
Jumper
Description
Default Setting
UID SW
Unit ID switch (push-button toggle switch ON/OFF)
Off
JBT1
Clear CMOS
Open (Normal)
JWD1
Watch Dog control
Pins 1-2 (Reset)
JPL1
LAN Enable/Disable
Pins 1-2 (Enabled)
LED
Description
Status
LED1
UID LED
Blue: UID Activated
LED6
Power LED
On: Power On
LED7
BMC Heartbeat
Blinking: BMC Normal/Working
LED9
M.2-C2 Error
On: Detected Error on M.2-C2
LED11
M.2-C1 Error
On: Detected Error on M.2-C1
Connector
Description
Battery (BT1)
Onboard CMOS battery
COM 1
Rear panel COM port #1
FAN 1~6
System cooling fan headers
JF1
Front control panel
JSD1, JSD2
SATA DOM power connector
JTPM1
Trusted Platform Module (TPM)/Port 80 connector
SATA0, SATA1
Internal SATA Ports
JL1
Chassis intrusion header
JOH1
Chassis overheat header
USB 0/1 (3.0)
Back panel USB 3.0 ports (USB 0/1)
USB 2/3 (3.0)
Back panel USB 3.0 ports (USB 2/3)
USB 4 (3.0)
USB 3.0 type A port (USB 4)
USB 6/7 (3.0)
Internal USB 3.0 header (USB 6/7)
JIPMI1
IPMI Header
JSXB1A, JSXB2, JSXB1C
Riser slots
JPWR2
24-pin ATX power supply connector
JPWR1
12V 8-pin ATX CPU power connector
M.2-C1, M.2-C2
M.2 Slots
PWRI2C
Power supply SMBus I2C header
LAN1, LAN2
Back panel LAN1, LAN2 connectors
VGA
Back panel VGA port
JSLIM 1/2/3/4/5/6/7/8
NVMe slots 1~15