Superior Performance, Superior Value
© 2005-2013 Superior-PHS
7
MAIN SET-UP SCREEN
MAIN SET-UP SCREEN
1.
Slow Down CNT:
Slow Down Count is used to automatically slow down on the X to last
piece of the Batch Size, where X is the valued entered. Typically set to “0” or “1”. When
running a 1 count or 2 count,
it is recommended to set the value to “0”. If running a
count of 3 or higher it is highly recommended the Slow Down Count value be set to 1. At
the maximum speeds of the XM High Speed feeder, the motor can coast on the last
piece, and for shorter pieces an extra piece can sometimes be dispensed. The Slow
Down Count is used to ensure the correct count is provided, and that the first piece of
the next Batch Size is staged in the correct position within the discharge of the feeder.
Press the value/number button to bring up keypad. Enter required value, press enter to
save and return to Main Set-up Screen.
2.
Trigger Delay:
The Trigger Delay is the time between receiving the Trigger Signal and
the time the feeder begins to feed. If you want to change where in the pocket the feeder
starts feeding, rather than move feeder or trigger photocell, you can add a Trigger delay
time. Press adjacent time button to bring up keypad. Enter required delay time, press
enter to save and return to Main Set-up Screen.