superior fires PI27 POSITANO LPG Installation & User'S Instructions Download Page 1

INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MODELS COVERED BY THESE INSTRUCTIONS

PI27 WESTBURY GROVE BRASS NG 

F500379

PI27 WESTBURY GROVE CHROME NG

F500380

PI27 WESTBURY GROVE BLACK NG

F500534

PI27 WESTBURY ELEGANCE BRASS NG         F500536

PI27 WESTBURY ELEGANCE BRASS/BLK NG

F500538

PI27 WESTBURY ELEGANCE BLACK NG

F500540

PI27 POSITANO NG

F500381

PI27 WESTBURY GROVE BRASS LPG 

F500420

PI27 WESTBURY GROVE CHROME LPG

F500421

PI27 WESTBURY GROVE BLACK LPG

F500535

PI27 WESTBURY ELEGANCE BRASS LPG        F500537

PI27 WESTBURY ELEGANCE BRASS/BLK LPG F500539

PI27 WESTBURY ELEGANCE BLACK LPG

F500541

PI27 POSITANO LPG

F500422

INSET FLUELESS GAS FIRE

Please note : Except where otherwise stated, all rights, includ-
ing copyright in the text, images and layout of this booklet is
owned by Superior fires Ltd  You are not permitted to copy or
adapt any of the content without the prior written permission
of Superior fires Ltd. 

1

Revision C - 03/13

©

2013 Superior Fires Ltd.

The products covered by this booklet are protected under
patent GB2275331C.

GB IE

BS EN 14829 : 2007

KM579167

Superior Fires

Christchurch, Dorset BH23 2BT

Tel: 01202 588 632     
Fax: 01202 499326

www.superiorfires.co.uk

e : [email protected]

WESTBURY GROVE

POSI  TANO

WESTBURY ELEGANCE

Summary of Contents for PI27 POSITANO LPG

Page 1: ...G F500537 PI27 WESTBURY ELEGANCE BRASS BLK LPG F500539 PI27 WESTBURY ELEGANCE BLACK LPG F500541 PI27 POSITANO LPG F500422 INSET FLUELESS GAS FIRE Please note Except where otherwise stated all rights i...

Page 2: ...background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning of...

Page 3: ...ust not be separated by a door To calculate a room size in cubic metres m3 divide the room volume in cubic feet ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms or...

Page 4: ...ive facia In this situation the thickness of the hearth or ledge may be as desired but it must have the strength to support the weight of the appliance and the facia Clearances to non combustibles Non...

Page 5: ...eat and moisture before proceeding with their installation If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to supp...

Page 6: ...pipe should always be sleeved through walls and floors using the shortest possible route For concealed supply pipe routing pipes must where possible be vertical and providing there is sufficient wall...

Page 7: ...rally under a block joint Clear out the block work in the area and insert the lintel by saw or stitch drill and chisel Do not dry bed the lin tel always bed on mortar and securely slate pin Clear out...

Page 8: ...e with out excessive heat loss from the room when the fire is off Installation as per method 2 recessing into a wall When setting the appliance into the wall find a suitable position between frame tim...

Page 9: ...opening and guide the gas pipe through the sealing grommet into its final routing position and fit the restrictor inlet elbow supplied to the gas pipe Secure the firebox by inserting screws in the pre...

Page 10: ...tion 7 3 All models The gap between the spark electrode and the pilot should be 3 5 4 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric s...

Page 11: ...turning anti clock wise to the high position The main burner should light after a few seconds To decrease the setting to LOW push the knob in slightly and turn the control knob clockwise to the low s...

Page 12: ...check operating pressures 17 Carry out combustion check as per section 9 4 Check safe operation of the appliance For specific servicing instructions see relevant sections Remove the fire front and pla...

Page 13: ...bon monoxide CO concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carb...

Page 14: ...here is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroug...

Page 15: ...such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See relevant section for furth...

Page 16: ...d such as metal heat deflec tors but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution Under no circumstances should any electrical equipme...

Page 17: ...monitoring safety device ODS If the fire shuts down during use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbanc...

Page 18: ...are no other specific requirements for care other than regular cleaning of the general appliance A wipe with a dry cloth is normally sufficient GLASS PANEL This can be cleaned with a suitable glass c...

Page 19: ...tor LPG Propane 0 80 F510089 Burner unit Natural Gas F510098 Burner unit LPG Propane F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 2013 Superior Fires Ltd 12 0 INSTALLA...