Page 1 of 2
VRT2536WS AND VRT2542WS
P/N 900853-01, REV. B, 06/2017
Fi
replac
e Dimensions
VENT-FREE FIREBOXES
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Fr
aming Dimensions
Framing Dimensions
Dim.
VRT2536
VRT2542WS
A
42-1/4 (1073)
48-1/4 (1226)
B
40-1/4 (1022)
40-1/4 (1124)
C
23-5/8 (600)
29-5/8 (753)
D
11-1/4 (286)
15-1/4 (387)
E
63-1/2 (1613)
69-3/4 (1772)
F
31-3/4 (807)
34-7/8 (886)
G *
20-1/2( 521)
20-1/2( 521)
H
44-1/4 (1124)
49-3/8 (1254)
*
Back wall of chase/enclosure including fi nishing materials, if any.
* A hood comes standard and is required for models
VRT2536WS and VRT2542WS. The factory-supplied hood
must be installed on the fi rebox for safe operation, for these
models, in ALL INSTALLATIONS.
A
B
Header
C
G
Rough Framing Face
(Unfi nished Shown)
Corner
Installation
A
C
D
H
F
G
E
Refer to Table Below
Back Wall Of Chase/Enclosure
Including Finishing Materials If Any
Rough Framing Face
(Unfi nished Shown)
A
Parallel
Installation
Model No.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
*Q
VRT2536
36
(914)
24
(610)
41-3/4
(1061)
37-1/4
(946)
23-1/2
(597)
20
(508)
3
(76)
7-3/8
(187)
15-7/8
(403)
7-1/2
(190)
12
(305)
1-3/8
(35)
5-1/2
(140)
30-3/8
(772)
29-5/8
(753)
VRT2542
42
(1067)
24
(610)
47-3/4
(1213)
37-1/4
(947)
29-1/2
(749)
20
(508)
3
(77)
7-3/8
(188)
15-7/8
(404)
7-1/2
(191)
12
(305)
1-3/8
(35)
5-1/2
(140)
30-3/8
(772)
29-5/8
(753)
* Dimensions are to assist you in selecting a log set that
is a compatible size.
Gas Line
Access -
Both Sides
Access Opening for Junction
Box - Right Side Only
(remove the knock-out
before installing J-Box).
J-Box / Electrical Kit is not
provided with appliance.
Junction Box
Top View
A
E
C
D
P *Q
F
H
J
M
N
1 (26)
7-1/8
(181)
Front View
B
G
Right Side View
L
K
Top Stand-Off
Spacers
(4 places)
5-3/4
(146)
3-5/8
(94)
Bottom of
Firebox
Opening
Top of Firebox
Opening
* Hood
Inches (millimeters)
Inches (millimeters)
Interior Firebox Dimensions**
Firebox Model
36”
42”
Front Width
35 (889)
41 (1042)
Rear Width
23-1/4 (591)
29-1/4 (743)
Depth
17-3/8 (441)
17-3/8 (441)
Height
24 (610)
24 (610)