Hardware Monitoring
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The options are 75
o
C,
80
o
C
, 85
o
C, and 90
o
C.
Highlight this and hit <Enter> to see the data for the following items:
CPU Temperature
System Temperature
Fan 1 Speed - FAN 6 Speed
: If the feature of Auto Fan Control is enabled, the
BIOS will automatically display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When
the CPU on-die temperature increases, the fan speed will also increase, and vise
versa. If the option is set to "3-pin fan," the fan speed is controlled by voltage.
If the option is set to "4-pin," the fan speed will be controlled by Pulse Width
Modulation (PWM). Select “3-pin” if your chassis came with 3-pin fan headers.
Select “4-pin” if your chassis came with 4-pin fan headers. Select “Worksta-
tion” if your system is used as a Workstation. Select “Server” if your system is
used as a Server. Select “Disable” to disable the fan speed control function to
allow the onboard fans to run at the full speed (12V) at all the time. The Options
are:
1. Full Speed at 12V (Disabled)
2. Optimized (for) Server with 3-pin, 3.
Optimized (for) Workstation with 3-pin, 4. Optimized (for) Server with 4-pin, 5.
Optimized (for) Workstation with 4-pin.
The Voltage status of the following items will be displayed:
VcoreA
1.5V
Vin0 (3.3V)
Vin1 (5V)
Vin2 (-12V)
Vin3 (12V)
5V Standby