eFlo 2.0 Electronic Flow Meter Operations Manual
Super Systems Inc.
Page 22 of 39
Settings Menu
To enter the Settings Menu, press
.
The Settings Menu contains seven options including:
Instrument Information & Diagnostics Menu
Basic Configuration Menu
Basic Configuration - Flow Alarm Menu
Network Configuration - Serial Comms Menu
Network Configuration - Ethernet Comms Menu
Instrument Configuration - Gas Menu
Instrument Configuration – Additional Options Menu
Details of each menu option are explained on the following
pages.
Figure 9: Settings Menu Screen
Instrument Information & Diagnostics Menu
This screen displays the following information:
Model: Instrument model.
Serial: Instrument serial number .
31677/31676/31675 Version: Circuit board software version.
Air flow: Calculated air flow from the remote analog
signal when the meter is used in Ratio Mode.
High pressure: Pressure sensor mA reading on the
“high” side of the orifice plate (N/A for the eFlo-H or
eFlo-L meters).
Low pressure: Pressure sensor mA reading on the “low”
side of the orifice plate.
Analog in: Analog input mA signal being received.
Analog out: Analog output mA signals being sent.
Temperature: Gas/Liquid temperature flowing through
the meter.
Valve maximum tare step setting.
Valve zero tare step setting.
Press
to return to the menu screen.
Figure 10: Information & Diagnostics Menu