background image

Thank you very much for using SUNX products.
Please read this Instruction Manual carefully and
thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient
place for quick reference.

CAUTIONS

2

٨

٨
٨

٨

٨

٨

Make sure to carry out wiring in the power sup-
ply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within
the rating.
If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.)
terminal of the power supply is connected to an
actual ground.
In case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicini-
ty of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage
lines or power lines or put them in the same race-
way. This can cause malfunction due to induction.

٨

٨

٨

٨

٨
٨

٨

٨

Take care that the sensor is not directly exposed to fluo-
rescent lamp from a rapid-starter lamp or a high frequency
lighting device, as it may affect the sensing performance.
Do not use during the initial transient time (50ms)
after the power supply is switched on.
Extension up to total 100m, or less, is possible with
0.3mm

2

, or more, cable. However, in order to re-

duce noise, make the wiring as short as possible.
Make sure that stress by forcible bend or pulling is
not applied directly to the sensor cable joint.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive
vapor, dust, etc., or where it may come in direct
contact with water, or corrosive gas.
Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
When connecting the mating cable to the connector type
sensor, the tightening torque should be 0.4N

m or less.

INSTRUCTION MANUAL

CX-400

Series

Amplifier Built-in

Photoelectric Sensor

٨

٨

Never use this product as a sensing
device for personnel protection.
In case of using sensing devices for personnel
protection, use products which meet standards,
such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.

WARNING

I/O CIRCUIT DIAGRAMS

4

٨

Connector pin position of the connector type

M12 pigtailed type

Not con-
nected

2

Output (Note)

V

1

0V

3

M8 connector type

Not con-
nected

2

Output (Note)

V

1

0V

3

Note: The thru-beam type sensor emitter does not incorporate the

output.

٨

NPN output type

D

T

r

Z

D

+

-

12 to 24V DC

r

10%

Internal circuit

Users' circuit

Load

(Black / 4)
Output (Note)

(Blue / 3) 0V

(Brown / 1) +V

Color code / Connector pin No. of
the connector type

100mA max.

Sensor

circuit

Note: The thru-beam type sensor emitter does not incorporate the

output.

Symbols...D

Z

D

T

r

: Reverse supply polarity protection diode
: Surge absorption zener diode
: NPN output transistor

Note: The thru-beam type sensor emitter does not incorporate the

output.

٨

PNP output type

Internal circuit

Users' circuit

Color code / Connector pin No. of
the connector type

D

T

r

Z

D

+

-

12 to 24V DC

r

10%

Load

(Black / 4)
Output (Note)

(Blue / 3) 0V

(Brown / 1) +V

100mA max.

Sensor

circuit

Symbols...D

Z

D

T

r

: Reverse supply polarity protection diode
: Surge absorption zener diode
: PNP output transistor

ADJUSTMENTS

5

٨

Operation mode switch

Operation mode switch

Description

Light-ON mode is obtained when the opera-
tion mode switch (located on the receiver) is
turned fully clockwise (L side).

Dark-ON mode is obtained when the opera-
tion mode switch (located on the receiver) is
turned fully counterclockwise (D side).

٨

Part description

Operation mode switch
(Note 1)
L: Light-ON
D: Dark-ON

Operation indicator
(Orange) (Note 2)
Lights up when the
sensing

output

is

ON

Sensitivity adjuster
(Note 1)
Sensing range be-
comes longer when
turned clockwise

Stability indicator (Green)
(Note 1)
Lights up under the stable
light condition or the stable
dark condition

Notes: 1)

2)

Not incorporated on the thru-beam type sensor emitter.
It is the power indicator (green: lights up when the power
is ON) for the thru-beam type sensor emitter.

SPECIFICATIONS

1

Automatic interference
prevention function

Long sens-
ing range

70 to 200mm

(Note 4)

800mm

(Note 4)

15m

5m

(Note 3)

300mm

(Note 4)

10m

3m

(Note 3)

100mm

(Note 4)

Sensing range

Narrow-view

CX-422

CX-422-P

CX-423

CX-423-P

CX-412

CX-412-P

CX-491

CX-491-P

CX-493

CX-493-P

CX-424

CX-424-P

CX-421

CX-421-P

CX-411

PNP output

NPN output

Model No.
(Note 1)

CX-411-P

Item

With polarizing
filters (Note 2)

Long sens-
ing range

Retroreflective

Thru-beam

Diffuse reflective

Type

20mA or less

25mA or less

12 to 24V DC

r

10% Ripple P-P 10% or less

Supply voltage

20mA or less

Current consumption

Emitter: 20mA or less

(

CX-412

غ

: 25mA or less)

Receiver: 20mA or less

1mm or less

0.5mm or less

0.5mm or less

Repeatability
(perpendicular to sensing axis)

Opaque,
translucent or
transparent
object (Note 5)

Ǿ

50mm

or

more opaque
or translucent
object (Note 3)

Ǿ

12mm or more opaque

object

Ǿ

50mm or more

opaque, translu-
cent or specular
object (Note 3)

Opaque, translucent or transparent
object

Sensing object

Infrared LED

(modulated)

0.2mm

2

3-core (thru-beam type sensor emitter: 2-core) cabtyre cable, 2m long

Cable

Enclosure: PBT, Lens: Acrylic, Indicator cover: Acrylic

Red LED

(modulated)

Red LED

(modulated)

Red LED (modulated)

Infrared LED (modulated)

Emitting element

IP67 (IEC)

Protection

-25 to +55

͠

(No dew condensation or icing allowed), Storage: -30 to +70

͠

Ambient temperature

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

Incorporated (Two units of sensors can be mounted closely.)

Continuously variable adjuster

Sensitivity adjuster

Green LED (lights up when the
power is ON), located on the emitter

Power indicator

Green LED (lights up under stable light received condition or stable dark condition), thru-beam type sensor: located on the receiver

Stability indicator

Orange LED (lights up when the output is ON), thru-beam type sensor: located on the receiver

Operation indicator

1ms or less

(Note 6)

Response time

Switchable either Light-ON or Dark-ON

Incorporated

Output

Output operation
Short-circuit protection

<NPN output type>

NPN open-collector transistor

Maximum sink current: 100mA

Applied voltage: 30V DC or less (between output and 0V)

Residual voltage: 1V or less (at 100mA sink current)

0.4V or less (at 16mA sink current)

<PNP output type>

PNP open-collector transistor

Maximum source current: 100mA

Applied voltage: 30V DC or less (between output and +V)

Residual voltage: 1V or less (at 100mA source current)

0.4V or less (at 16mA source current)

RF-230

(Reflector): 1 pc.

Material

50g approx.

Emitter: 45g approx., Receiver: 50g approx.

Weight
Accessory

Notes: 1) The model No. with suffix '

-J

' is the M12 pigtailed type, '

-Z

' is the M8 connector type.

(e.g.) M12 pigtailed type:

CX-411-J

, M8 connector type:

CX-411-Z

Use the connection cables as shown below. (Two sets are required for the thru-beam type sensor.)

<Connection cable for the M12 pigtailed type>

Type

Model No.

Cable length

2-core type

CN-22-C2

2m

CN-22-C5

5m

4-core type

CN-24-C2

2m

CN-24-C5

5m

<Connection cable for the M8 connector type>

Type

Model No.

Cable length

Straight type

CN-24A-C2

2m

CN-24A-C5

5m

Elbow type

CN-24AL-C2

2m

CN-24AL-C5

5m

2)

3)

4)

5)

6)

The model No. with suffix '

E

' shown on the label affixed to the thru-beam type sensor is the emitter, '

D

' shown on the label is the receiver.

Thru-beam type sensor emitter:

CX-41

غ

E

, Thru-beam type sensor receiver:

CX-41

غ

D

The model No. of retroreflective type sensor with the suffix '

-Y

' is the sensor without the

RF-230

reflector.

(e.g.)

CX-491-Y

The retroreflective type sensor with polarizing filters may not stably detect specular
or glossy objects through transparent film since light is polarized by the transparent
film. For details, refer to '

RETROREFLECTIVE TYPE SENSOR WITH POLAR-

IZING FILTERS

'.

The sensing range and the sensing object of the retroreflective type sensor is specified
fot the

RF-230

reflector. The sensing range represents the actual sensing range of the

sensor. The sensing ranges itemized in 'A' of the table below may vary depending of the
shape of sensing object. Be sure to check the operation with the actual sensing object.
The sensing range of the diffuse reflective type sensor is specified for white non-
glossy paper (200

˜

200mm) as the object.

The minimum sensing object of the diffuse reflective

narrow-view type sensor is

Ǿ

0.5mm copper wire.

By mounting interference prevention filters (

PF-CX4-

غ

), two sets of the sensor can be mounted close together. For details, refer

to '

INTERFERENCE PREVENTION FILTER (OPTIONAL)

'.

8

10

Sensing range

(A)

Reflector setting range

(B)

Sensor

Reflector

Sensing
object

A
B

3m

0.1 to 3m

5m

0.1 to 5m

CX-491

غ

CX-493

غ

MOUNTING

3

٨

The tightening torque should be 0.5N

m or less.

Sensor mounting
bracket
(Optional)

M3 (length 12mm)
screw with washers

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]