![SunTech ST300 Series Operation Manual Download Page 50](http://html1.mh-extra.com/html/suntech/st300-series/st300-series_operation-manual_1400856050.webp)
Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
50 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
4-16-6. How to get information about Polygon Service
Field
Marks
Value
Meaning
HDR
“ST300PLC”
Command type
DEV_ID
String
Device ID
VER
“02”
Protocol Version
CMD
“GetPolygonSer
viceInfo
”
Command
<Example>
[command] ST300PLC;850000;02;GetPolygonServiceInfo
[response] ST300PLC;Res;850000;104;GetPolygonServiceInfo;1;3600
A response string which comes after GROUP_ID consists of the following Fields as shown in the table below.
OUT_PROTECT
ALIVE_RPT_INTERVAL_OUTSIDE
4-17. Temperature parameter
In order to set these various parameters properly, read carefully the contents and <Example> along with <Note>
described in the bottom inside the table below. In setting a new device, the
‘SyncTrak’ will show you detailed
explanation on how to set parameters relating to these
‘Fields’.
HDR
DEV_ID
VER
1ST_ID
1ST_HIGH_ALERT
1ST_LOW_ALERT
2ND_ID
2ND_HIGH_ALE
RT
2ND_LOW_
ALERT
3RD_ID
3RD_HIGH_ALERT
3RD_LOW_ALERT
Field
Marks
Value
Meaning
HDR
“ST300RPT”
Command type.
DEV_ID
9 char
Device ID.
VER
“02”
Protocol Version.
1ST_ID
String
The Sensor ID of the sensor to utilize alert function in case
the temperature of the temperature sensor changes more
than the preset value of the temperature sensor.
1ST_HIGH_ALERT
String
How to set High Temperature value in order to send an alert
The range covers -55 to +125 degrees in Celsius
1ST_LOW_ALERT
String
How to set Low Temperature value in order to send an alert
The range covers -55 to +125 degrees in Celsius
2ND_ID
String
The Sensor ID of the sensor
utilize alert function in case the
temperature of the 2
차
온도센서
temperature sensor
changes more than the preset temperature.
2ND_HIGH_ALERT
String
How to set High Temperature value of the 2nd temperature
sensor to send an alert