![SunTech ST300 Series Operation Manual Download Page 48](http://html1.mh-extra.com/html/suntech/st300-series/st300-series_operation-manual_1400856048.webp)
Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
48 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
4-16-2. How to set Polygon Service
Field
Marks
Value
Meaning
HDR
“ST300PLS”
Command type
DEV_ID
String
Device ID
VER
“02”
Protocol Version
OUT_PROTECT
‘0’ or ‘1’
If
‘1’, position tracking stops when the vehicle moves out
from an activated polygonal geo-fence. In this case, reporting
with GPS is deactivated. We name this function <Out
Protect>.
You can set the parameters to utilize the function of <Out
Protect> for all the Polygon groups (i.e.: 50 groups) and all
the Polygon positions (i.e.: 60 positions) as well.
ALIVE_RPT_INTER
VAL_OUTSIDE
String
Sec
Interval for sending alive report in parking
Range : 0 ~ 86400
If <OUT_PROTECT> is enable, Alive Report is sent at an
interval of < ALIVE_RPT_INTERVAL_OUTSIDE> as soon as
the vehicle gets outside from a polygon geo-fence group.
The Alive Report is sent at this interval regardless of
parking/driving state of the vehicle.
If
‘0’, Alive Report is not sent.
<Example>
[command] ST300PLS;850000;02;1;3600
[response] ST300PLS;Res;850000;104;1;3600
4-16-3. How to get Information about Polygon Group
Field
Marks
Value
Meaning
HDR
“ST300PLC”
Command type
DEV_ID
String
Device ID
VER
“02”
Protocol Version
CMD
“GetPolygonGro
upInfo
”
Command
GROUP_ID
‘1’ ~ ‘10’
Polygon group ID
<Example>
[command] ST300PLC;850000;02;GetPolygonGroupInfo;1
[response] ST300PLC;Res;850000;104;GetPolygonGroupInfo;1;1;1;60;0;3600;28.5;2;30.33;1;8;position 1
A response string which comes after GROUP_ID consists of the following fields as shown in the table below
ENABLE
ALLOW_
PARAM
RPT_INTERVAL_
IN_PARKING
RPT_INTERVAL_
IN_DRIVING
ALIVE_INTERVAL_
IN_PARKING
SPEED_LIMIT
BUZZER_SPEED
_LIMIT
ACCEL_SPEED
ACCEL_TIME
DECEL_SPEED
DECEL_TIME