4-7. Motion sensor parameters
In order to set these parameters properly, read carefully the contents and <Example> along with <Note> described
in the bottom inside the table below. In setting a new device, the
‘SyncTrak’ will give you detailed explanation on
how to set parameters relating to these
‘Fields’.
HDR
DEV_ID
VER
SHOCK_DELAY
MOTION_THRES
SHOCK_THRES
COLL_THRES
Field
Marks
Value
Meaning
HDR
“ST300MSR”
Command type.
DEV_ID
9 char
Device ID.
VER
“02”
Protocol Version.
SHOCK_DELAY
String
Sec.
Delay in entering shock detection mode after ignition off:
0
– Disable.
Range: 1 ~ 21600 (5hour).
Recommend: 600 (10 min).
MOTION_THRES
String
Step
Detection level of motion violation:
Range: 0.04 ~ 2.0.
Recommend: 0.04.
SHOCK_THRES
String
Step
Detection level of shock violation:
Range: 0.04 ~ 2.0.
Recommend: 0.04.
COLL_THRES
String
Step
Gravity for collision report.
Range : 0.1 ~ 2.0
Recommend : 0.7
<Example>
[command] ST300MSR;100852588;02;600;0.04;0.04;0.7
[response] ST300MSR;Res;100852588;128;600;0.04;0.04;0.70
<Note>
* As for the shock level, it is recommended that the user should set to 0.04. If the motion threshold is higher
than0.04, the sensor will be too sensitive to make a proper detection on shock.