![SunTech ST300 Series Operation Manual Download Page 24](http://html1.mh-extra.com/html/suntech/st300-series/st300-series_operation-manual_1400856024.webp)
Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
24 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
4-5. Parameters for various features
In order to set these various parameters properly, read carefully the contents and <Example> along with <Note>
described in the bottom inside the table below. In setting a new device, the
‘SyncTrak’ will show you detailed
explanation on how to set parameters relating to these
‘Fields’.
HDR
DEV_ID
VER
PARKING_LOCK
SPEED_LIMIT
PWR_DN
CON_TYPE
ZIP
GROUP_SEND
MP_CHK
ANT_CHK
BAT_CHK
M_SENSOR
CALL
GEO_FENCE
DATA_LOG
Field
Marks
Value
Meaning
HDR
“ST300SVC”
Command type.
DEV_ID
9 char
Device ID.
VER
“02”
Protocol Version.
PARKING_LOCK
‘0’ or ‘1’
Parking lock
Disable (0) / Enable (1):
If enable (1), the device periodically checks vehicle position
under parking status. When the vehicle gets out from some
boundaries or starts moving faster than the predefined
velocity, the device reports the Parking Lock Emergency.
SPEED_LIMIT
String
km/h
Over speed limit
If 0, the device does not check the over-speed.
If greater than 0 and if the vehicle runs faster than the
predefined value, the device reports an alert once.
PWR_DN
‘0’ ~ ‘2’
Power saving type
0: Disabled sleep and deep sleep service.
1: Enabled deep sleep.
2: Enabled sleep.
CON_TYPE
‘0’ ~ ‘2’
Connection Type with Server
0 = KEEP_CON.
1 = KEEP_DISCON.
2 = KEEP_NOP.
Detailed explanation is made below.
ZIP
‘0’ or ‘1’
Use Zip
Disable (0) / Enable (1)
GROUP_SEND
‘0’ or ‘1’
Group Send for stored data
0: Disable.
1: Enable, One packet can include up to 5 reports
The
‘Group Send’ function is explained as below.
MP_CHK
‘0’ or ‘1’
Checking Main Power Disconnection:
Disable (0) / Enable (1).
ANT_CHK
‘0’ or ‘1’
GPS Antenna Connection Error Check:
Disable (0) / Enable (1).