Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
141 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
9-9. Storage of Reports un-sent
Device has maximum storage capacity of the un-sent reports in such cases as follows:
2,000 status reports (**),
50 emergency reports,
50 alert reports (including event reports), and
1500 bytes for the response that the command has required the device to respond with as command
response
Note
(**):
Due to bad report-routing environment, device could not make a real-time based reporting. For example,
the reporting router does neither run properly, is nor connected properly. In such a situation there might be
a report which has consequently failed to arrive in the server successfully after making several attempts to
send the report to the server. In that case, the device stores such a report for a while until such
environment (e.g. GPRS network) gets back to normal to enable the device to try to send the report to the
server again.
When
‘status reports’ start being accumulated, max 2000 reports can be hold in the buffer storage of the
device. If those
‘status reports’ are triggered out to the server, the oldest report is erased first and a new
report is buffered if the buffer is completely full of those reports. And then, a new status report enters
(FIFO: First In First Out as a sequential system).
9-10. Odometer and RPM Calibration
RPM Calibration
This is the steps to calibrate RPM.
1. Turn ON and turn OFF ignition line (blue line)9 times continuously.
On(1
st
)
Off(2
nd
)
ON(3
rd
)
Off(4
th
)
ON(5
th
)
Off(6
th
)
On(7
th
)
Off(8
th
)
On(9
th
)
2. Wait during 5 seconds.
3. And GPRS LED (blue) blinks 0.5s continuously and GPS LED (red) is turned off.
4. Press accelerator keeping 2000RPM for 10seconds. It should be progressed within 3minutes.
5.
As calibration is completed successfully, the GPRS LED illuminates. The LEDs return to normal mode
after turn off and on again. In case of fail, the device blinks the LED with normal method and Installer
should repeat calibration process from 1
st
step.
Odometer Calibration
There are two ways to calibrate odometer automatically, by ignition line and by commands. Each calibration follows
below steps.
Calibration by ignition:
1. Wait until GPS is fixed (GPS LED (red) blinks one time).