background image

®

User Guide

Summary of Contents for Oscar2

Page 1: ...User Guide...

Page 2: ......

Page 3: ...the Sytem 11 Hardware Requirements 11 Software Requirements 11 Powering the Oscar 2 for use 11 Setting Up the System 12 Installing the Software 12 Conducting an Ambulatory Blood Pressure Study 13 Prog...

Page 4: ...he data obtained from ambulatory blood pressure monitors is highly accurate and useful for managing a wide variety of hypertensive situations including White coat hypertension Resistant hypertension M...

Page 5: ...n the cuff is reduced from above systolic toward zero or atmospheric pressure They are divided into phases Phase 1 K1 or systolic begins with the sudden appearance of a faint clear tapping or thumping...

Page 6: ...t Cuff 25 35 cm 98 0063 12 1 Adult Plus Orbit Cuff 33 40 cm 98 0063 13 1 Oscar 2 Pouch 98 0032 00 1 Oscar 2 Strap 98 0036 00 1 Oscar 2 Belt 98 0037 00 1 Oscar 2 User s Guide 80 0027 00 1 Oscar 2 Quick...

Page 7: ...powered Operating Conditions 10 C 50 F to 50 C 122 F 20 95 RH non condensing Power Two AA alkaline batteries or high capacity rechargeable batteries NiMH Data Memory Flash memory stores up to 250 rea...

Page 8: ...er physical condition and use outside the operating instructions detailed in this manual Safety and effectiveness on pregnant women and neonates have not been tested Disposal This symbol indicates tha...

Page 9: ...for care instructions DO NOT remove unit covers The monitor does not contain any user serviceable components DO NOT use the monitor if it has failed its diagnostic self test or if it displays a great...

Page 10: ...e when flashing the monitor will turn off in the next 20 seconds unless an ABP study is started Pressure Indicates the pressure of the cuff in mmHg during a BP reading BP Reading Immediately after a B...

Page 11: ...mended One available USB or serial port 32 MB RAM and minimum 20 MB HDD recommended Software Requirements Microsoft Windows version 98 or later excluding Windows ME Microsoft Internet Explorer 3 or la...

Page 12: ...ollow the instructions appearing on the screen if CD autoplay is enabled on your computer If autoplay is not enabled follow these steps 1 Open Windows Explorer or Windows NT Explorer Press the Windows...

Page 13: ...back of your computer Configuring your computer for communication Using the PC Interface USB cable Installing AccuWin Pro v3 will load the driver s for the USB cable Once the cable is connected to the...

Page 14: ...st push of the Start Stop button with unit powered on will start the study Time zone difference Adjust the monitor s clock to the time zone that the patient is in relative to your time zone Max Pressu...

Page 15: ...is at the top of the cuff The cuff should be midway between the elbow and shoulder Be sure the ARTERY indicator is over the patient s brachial artery between the bicep and tricep muscles see step 2 Wr...

Page 16: ...uring a study without the data being lost or interrupting the monitor s program Alternatively the monitor can be turned off without losing its data Instruct the patient on how and when to fill out the...

Page 17: ...s if this is a new patient If you click No a list of current patient files will appear Fig 8 Select the patient file to save the retrieved data 6 If you click Yes the Patient information dialog box Fi...

Page 18: ...ime out Retry reading push START STOP button If problems persist return unit for servicing 89 Reading Aborted cuff over pressure Check for blocked or kinked air hose 90 Service Required power supply o...

Page 19: ...may use a mild disinfectant solution to clean the cuff strap belt and pouch Alternatively you may also wash these items in a washing machine Remove the bladder from the Orbit cuff before machine wash...

Page 20: ...he unit 3 Attach the third end of the T tube into a calibrated mercury column which gives you access to the bulb and a reference 4 Using the bulb of the calibrated mercury column inflate the cuff to 2...

Page 21: ...the suspected defect The instrument should be carefully packaged and shipped prepaid to SunTech Medical 507 Airport Boulevard Suite 117 Morrisville NC 27560 8200 USA Tel 1 800 421 8626 or 1 919 654 23...

Page 22: ...o 13 14 C Customer Service 21 H Hardware Power 11 Requirements 11 I Introductions Ambulatory BP Monitoring 4 Oscar 2 5 L LCD Layout 10 M Maintaining and Cleaning 19 Checking calibration 20 O Oscar 2 A...

Page 23: ...23...

Page 24: ...www SunTechMed com SunTech Medical Ltd Oakfield Industrial Estate Eynsham Oxfordshire OX29 4TS UK Tel 44 0 1865 884 234 Fax 44 0 1865 884 235 www SunTechMed com SunTech Medical Ltd Level 25 Bank of C...