7.3.4. Settings.
1. Setting the water thermostat.
Pressing the buttons
+
and
-
for the
first time displays the temperature set
-
ting. Additional button presses (within 8
seconds) changes the values. After wait
-
ing for 5 seconds, the new setting will be
saved when the blink stops.
2. Switching between
individ-
ual programs is performed by pressing
the buttons
Р
. The selected program is
indicated by the indicator light and the
display when the button
Р
is pressed
for the first time . (see the mode table).
Pressing the button
Р
within 8 seconds
switches between individual programs.
3. Preview and parameter set-
tings.
You can enter the parameter menu by
briefly and simultaneously pressing the
buttons
+
and
-
after which the
same buttons can be used to toggle be
-
tween parameters.
When the desired parameter is selected,
you must wait for 8 seconds for the dis-
play to show the perimeter value. After
another 8 seconds, the display returns to
the main menu, which displays the cur-
rent water value in the tank.
4. Set the interval for automatic
thermal disinfection
You can enter the parameter menu by
briefly and simultaneously pressing the
buttons
+
and
-
. Switching between
screens is done with the same buttons.
Select parameter “
L2
” and after a few sec
-
onds set the overheating interval (factory
setting is 14 days). After setting the de
-
sired value, wait 5 seconds, and after the
blink stops, the setting will be saved.
9. INITIAL CONTROL
Check before operating the device:
- Proper grounding of the machine;
- Protection of the contact;
- Proper pipe layout.
- In the beginning and after a few days
of operation, check the screws on the in
-
spection hole.