background image

12

ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ

ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

Scheme 7.  Example of a TDA thermo-pump connection diagram

 

А - Inlet water

B - DHW

C - Recirculation

D - Draining water

1- Water Heater

2- Circulation group +

expansion vessel for a solar system

3- Coil type heat exchanger

4- El. Heater

5- Built-in heat pump 

6- Solar collectors

7- Magnesium anode

8- Circulation group

9- Safety valves

10- Non-return valve

11 - Expansion vessel

Summary of Contents for TDA 200

Page 1: ...HEAT PUMP FOR DOMESTIC HOT WATER DHW serie TDA TECHNICAL PASPORT INSTALLATION AND OPERATION MANUAL Versie 0 2...

Page 2: ...2 INSTALLATION and OPERATION MANUAL...

Page 3: ...F THE HEAT PUMP 6 3 TRANSPORTATION OF THE THERMO PUMP TDA 6 4 SUBJECT OF DELIVERY 7 5 TECHNICAL DESCRIPTION OF THE PRODUCT 7 6 INSTALLATION THE THERMO PUMP TD 8 7 CONTROLLER 14 8 TECHNICAL PARAMETERS...

Page 4: ...n the TDA model provides the possibility of using independent heat sources The instruction describes the process of installing and servicing the product Installation and connection may only be carried...

Page 5: ...stop valve between the water tank and the safety valve The water heater is intended for the storage of drinking water so it must comply with the applicable national drinking water regulations or in ca...

Page 6: ...igence or lack of protection from harmful external influences The device should not be locked or objects placed on it If the temperature exceeds 85 degrees during operation contact a workshop immediat...

Page 7: ...vironment 5 2 Water tank The TDA water tank is a steel tank for do mestic hot water The water purity and protection of the metal from the corrosive action of the water is ensured by a uni form titaniu...

Page 8: ...PUMP TDA The minimum height of the room in which the thermodynamic boiler can be in stalled is 2000 mm for TDA E200 and TDA S200 models 2300 mm for TDA E300 and TDA S300 The product is designed to dra...

Page 9: ...NUAL P D Z E A Si So R Z B H1 H H V V 3 0 7 5 Z E L Si So H H1 A Si So R Z B Z E P D H V V 3 0 7 5 Z E L Si So Sheme 4 Mounting dimensions of model TDA 200 Sheme 5 Mounting dimensions of model TDA 300...

Page 10: ...150 150 Hot water outlet B mm Rp 1 990 1260 El bindings E mm 1092 1362 Electric heating anode U P mm Rp 11 4 180 700 720 Recirculation R mm Rp 3 4 785 1000 Inlet coil Si mm Rp 1 635 635 Outlet coil So...

Page 11: ...ION and OPERATION MANUAL Sheme 7 Suction and blowing air to a neighboring room Scheme 8 Suction and outlet of air in the same room Scheme 9 Suction and blowing air to a neighboring room Sheme 10 Sucti...

Page 12: ...Inlet water B DHW C Recirculation D Draining water 1 Water Heater 2 Circulation group expansion vessel for a solar system 3 Coil type heat exchanger 4 El Heater 5 Built in heat pump 6 Solar collectors...

Page 13: ...the anode is installed during installation The connection schemes in this manual are exemplary When connecting the product to a solar system or boiler it is necessary to consult and supervise a techn...

Page 14: ...am 1 Compressor 2 Fan 3 Compressor condenser 4 Pressostat 5 Temperature sensor for water 7 El power supply 11 Temperature sensor evaporator 13 El PV terminal 15 Electromagnetic valve 16 Fan socket 17...

Page 15: ...splay 3 Quick button P to change the operating mode 4 Quick button HT for thermal disinfection protection against legionella and rapid heating 5 HT indicator for thermal disinfection or rapid heating...

Page 16: ...ower than the set minimum temperature L1 the appliance automatically switches to heater mode with electric heater flashes lit 6 The appliance is in automatic mode and the water is heated by the heat p...

Page 17: ...s not affect the operation 3 Heat pump water heating and automatic backup heat switching program P5 when the evaporator temperature is too low The heat pump operates completely independently with prio...

Page 18: ...is not completed iThe indicator lights during the temperature disinfection i IMPORTANT In case the program is not executed for 12 hours the function stops and switches to normal operating mode 5 Fast...

Page 19: ...pressing the buttons and after which the same buttons can be used to toggle be tween parameters When the desired parameter is selected you must wait for 8 seconds for the dis play to show the perimet...

Page 20: ...cooling system Make sure the water tank is full of water You can clear the error by pressing the button If it appears again contact your service center Alternative 8 and The DHW sensor is not connect...

Page 21: ...21 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL 8 TECHNICAL PARAMETERS OF THERMO PUMP TDA...

Page 22: ...rating range Air temperature min max 70 350 70 350 Water temperature min inlet max outlet 100 600 100 600 Refrigeration circuit Refrigerant type R134a R134a Refrigerant quantity 1 3 kg 1 3 kg Heatsour...

Page 23: ...water outlet B mm Rp1 990 Rp1 1260 Flange O mm 180 Rp11 4 700 Rp11 4 720 Anode P mm Rp11 4 700 Rp11 4 720 Recirculation R mm Rp3 4 785 Rp3 4 1000 Drain sleeve Y mm Rp1 30 Rp1 30 Heat exchanger coils S...

Page 24: ...tion of magnesium anode and pe riodic replacement Check the safety of the valve system Check the coolant charge Check that the service flange bolts and the boiler water connections are loose 10 RECYCL...

Page 25: ...Directive 2006 42 EC of 17 May 2006 on the essential requirements and assessment of conformity of machinery European Parliament Council Directive 2004 108 ECof15December2004onthe approximation of the...

Page 26: ...26 INSTALLATION and OPERATION MANUAL...

Page 27: ...27 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL...

Page 28: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Reviews: