Website: www.sunsynk.com E-mail: [email protected]
8
2. TECHNICAL SPECIFICATION
SUNSYNK-3.6K-SG02LP1 and SUNSYNK-5K-SG03LP1
Model
SUNSYNK-3.6K-SG02LP1
SUNSYNK-5K-SG03LP1
Battery Input Data
Battery Type
Lead-acid or Lithium-ion
Battery Voltage Range (V)
40~60V
Max. Charging Current (A)
90A
120A
Max. Discharging Current (A)
90A
120A
Charging Curve
3 Stages/Equalisation
External Temperature Sensor
Optional
Charging Strategy for Li-Ion Battery
Self-Adaptation to BMS
PV String Input Data
Max. DC Input Power (W)
4680W
6500W
PV Input Voltage (V)
370V (100V~500V)
MPPT Range (V)
125~425V
Full Load DC Voltage Range (V)
240~425V
Start-up Voltage (V)
150V
PV Input Current (A)
11A+11A
No. of MPPT Trackers
2
No. of Strings Per MPPT Tracker
1+1
AC Output Data
Rated AC Output and UPS Power (W)
3600W
5000W
Max. AC Power (W)
3960W
5500W
Peak Power (off-grid)
2 times of rated power, 10 S
AC Output Rated Current (A)
15.7A
21.7A
Max AC Output Current (A)
18A
25A
Max Continuous AC Passthrough (A)
35A
Power Factor
0.8 leading to 0.8 lagging
Output Frequency and Voltage
50/60Hz; 220/230/240Vac (single phase)
Grid Type
Single Phase
Current Harmonic Distortion
THD<3%(Linear load<1.5%)
Efficiency
Max. Efficiency
97.60%
MPPT Efficiency
96.50%
Euro Efficiency
99.90%
Protection
PV Input Lightning Protection
Integrated
Anti-islanding Protection
Integrated
PV String Input Reverse Polarity Protection
Integrated
Insulation Resistor Detection
Integrated
Residual Current Monitoring Unit
Integrated
Output Over Current Protection
Integrated
Output Shorted Protection
Integrated
Output Over Voltage Protection
Integrated
Certifications and Standards
Grid Regulation
VDE 0126, AS4777, NRS2017, G98, G99, IEC61683, IEC62116, IEC61727,
RD1699:2011, XP C15-712-3:2019-05
Safety Regulation
IEC62109-1, IEC62109-2
EMC
EN61000-6-1, EN61000-6-3
General Data
Operating Temperature Range (
℃
)
-25~60°C, >45°C Derating
Cooling
Fan