If the device does not turn on:

1. Make sure the plug is firmly inserted into the electrical outlet.

2. Make sure the device has been operating within the limits indicated 

in this instructional manual (30 minutes ON/30 minutes OFF).

If the device does not nebulize, or the nebulization

is weak:

1. Make sure the ends of the air tube are fitted tightly onto the main

unit and onto the nebulizer (see connected kit and unit diagram 

below)

2. Check whether the nebulizer mask or mouthpiece kit cup chamber is

empty or overfilled with medication.

3. Check whether the nebulizer nozzle is obstructed (see

medicine cup diagram below)

4. Check whether the baffle is inserted properly. The baffle fits over the 

medicine cup’s interior cone (see medicine cup diagram below).

Fit tube

ends tightly

Fit tube

ends tightly

Instruction Manual

SUNNY

Pediatric

Compressor

Nebulizer

NEB300BEAR

NEB300BEAR-R

NEB300BEAR-IFU V 1.00

2019-06-04

Deluxe Nasal Pillow CPAP Mask

Item# 

CM036

Intended Use

The nasal pillow mask is intended to provide an interface for Continuous Positive Airway Pressure (CPAP) or bilevel system. 

The mask to be used by adult patients (>66lb/30kg) for whom positive airway pressure has been prescribed. The mask is for 

single-patient re-use in the home environment and multi-patient re-use in the hospital/institutional environment.

       

Caution

US federal law restricts this device to sale by or on the order of a physician.

Excluding patient population

This mask may not be suitable for patients with the following conditions: impaired cardiac sphincter function, excessive 

reflux, impaired cough reflex and hiatal hernia. It should not be used if the patient is unresponsive, obtunded, unable to 

remove the mask, or uncooperative.

       

Warnings

This mask is designed for use with CPAP or bilevel systems recommended by your health care professional or respiratory 

therapist. Do not wear this mask unless the CPAP or bilevel system is turned on and operating properly. Do not block or try 

to seal the exhalation port.

CPAP systems are intended to be used with special masks with connectors which have vent holes to allow continuous flow of air out of the mask. When the 

device is turned on and functioning properly, new air from the device flushes the exhaled air out through the attached mask exhalation port. However, when 

the device is not operating, enough fresh air will not be provided through the mask, and exhaled air may be re-breathed. At low pressures, the airflow through 

the exhalation port may not be enough to clear all of the exhaled gas (CO2) from the mask. You may breathe in some of the air that you have exhaled.

If oxygen is used with the device, the oxygen flow must be turned off when the device is not operating.

• When the device is not in operation, and the oxygen flow is left on, oxygen delivered into the ventilator tubing may accumulate within the device enclosure.

Oxygen accumulated in the device enclosure will create a risk of fire.

• Oxygen supports combustion. Oxygen should not be used while smoking or in the presence of an open flame.

• At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on the pressure settings, patient breathing pattern,

nasal interface selection, and the leak rate.

Some users may experience skin redness. If this happens, contact your health care professional.

Cleaning the Mask

The cushion, nasal interface, and tubing should be cleaned daily or as needed.

• Hand wash in warm water with a mild liquid dishwashing detergent. Do not use bleach, alcohol, or cleaning solutions

containing alcohol. Do not use cleaners containing conditioners or moisturizers.

• Rinse thoroughly. Pat with a towel and air dry completely before use

• Inspect all parts for damage or wear; replace if necessary.

Cleaning the Headgear

Hand wash the headgear weekly or as needed. Lay the headgear flat or line dry.

Disposal

The nasal pillow mask does not contain any hazardous substances and may be disposed of with your normal

household refuse.

latex

free

Manufactured for

Sunset Healthcare Solutions

180 N Michigan Ave Ste 2000

Chicago, IL 60601

SunsetHCS.com

DO NOT PRINT THIS LAYER.

100%

1 Color

1

PH  2.23.17

A4  (210mm x 297mm)

res036-ifu.pdf

When printing with default 

Acrobat autoscale settings.

Cleaning

Cleaning of the compressor

Use a clean dry cloth and mild detergents to clean the outside of

the unit.

ATTENTION

 During cleaning, make sure the internal parts of the unit 

are not in contact with liquids and the power cord is disconnected.

Cleaning and disinfection of the accessories

After each use, disassemble T-piece kit into 3 sections. Wash in warm 

soapy water and rinse well. Wipe with a paper towel and allow to air dry.

            Do not boil or autoclave angled mouthpieces, air tubes, or masks.

            It is important that the cleaning instructions are carefully    

            followed to ensure optimal operation.

Replacement of Nebulizer Kit

RES2210 Pediatric Aerosol Mask

(Included in NEB300BEAR and NEB300BEAR -R)

The pediatric aerosol mask should be replaced after a long period of 

inactivity, or if it is obstructed by dry medication, dust, etc. With normal 

use, the pediatric aerosol mask should last 1 month.

RES091 Disposable Nebulizer Kit 

with Clear Tubing

(Included in NEB300BEAR and NEB300BEAR -R)

The disposable nebulizer T-Piece kit should be replaced after a long 

period of inactivity, or if it is obstructed by dry medication, dust,etc. With 

normal use, the disposable nebulizer T-piece kit should last 1 month.

RES093 Reusable Nebulizer Kit 

with Green Tubing

(Included in NEB300BEAR-R)

The reusable nebulizer T-Piece kit should be replaced after a long period 

of inactivity, or if it is obstructed by dry medication, dust, etc. With 

normal use, the reusable nebulizer T-piece kit should last 6 months.

Replacement of the filter

The filter is to be replaced after approximately 30 hours of use, or when 

it appears dirty. Open the filter holder to replace the filter with a new 

one. Use Sunset BF018 Nebulizer Filters.

Do not use the device without the filter.

Maintenance and Repair

Never open the device. There are no serviceable parts within the unit. 

The compressor does not require lubrication or maintenance.