Page 5
www.sunrotor.com
3
W
ARNINGS
Please review the following warnings. These are listed for both personal safety and the safety of the
products. Disregarding or ignoring these warnings can result in
SERIOUS INJURY
and/or
VOID YOUR
WARRANTY
. All SunRotor
®
Solar Pumps should be installed by a licensed pump installer. If this
system is being installed without a licensed pump installer, an electrician or knowledge of electrical
circuits is
HIGHLY
recommended. If any questions or concerns regarding these warnings should arise,
please contact your Authorized SunRotor
®
Dealer or the SunRotor
®
Technical Services Team at 1-580-
303-4015. Solar Power & Pump Company, LLC is
NOT LIABLE
for any
DAMAGE
or
INJURY
.
All SunRotor
®
controllers have a maximum voltage rating. Exceeding these ratings will destroy the
controller and void the warranty. Do
NOT
exceed the following open circuit voltages:
SRC-M50T
:
50VDC
;
SRC-M100T
:
100VDC
;
SRC-M200T
;
200VDC
. For all other controllers, please contact the
SunRotor
®
Technical Services Team. See
Section 9.2 Wiring the Controller
.
The system should be installed and serviced by qualified personnel only. All electrical codes should be
observed. Make
ABSOLUTELY
CERTAIN
all power sources are disconnected prior to wiring.
Extreme heat can damage the pump. Protect the pump from sunlight or other heat sources.
SunRotor
®
solar pumps are
CLEAN WATER PUMPS
. Extreme sand or silt may cause the pump to stop or
fill the pipe with debris. Running it under these conditions may damage the pump and
VOID YOUR
WARRANTY
. Do
NOT
use the pump to develop a new well or purge a dirty well.
Install proper system grounding for safety and lightning protection. Although the warranty does
NOT
cover damage caused by
A
CTS OF
G
OD
, proper grounding can significantly reduce the chance of
extreme damage. See
Section 5.8 Grounding and Lightning Protection
.
Follow all wire sizing recommendations on pump data sheets. Under-sizing the wires can cause the
pump to experience low power failure.
Do not touch controller input or pump wires together to test for a spark.
Do not run the pump dry.
The cable splice must make a water-tight seal to the
OUTER JACKET
of the pump cable. See
Section 7.3
Splicing the Wires
.
There are potential hazards in handling any heavy mechanical assembly. If you have any doubts about
your ability to perform the Hand Installation
SAFELY
, please hire a professional pump installer. Do not
use a winch or a vehicle. See
Section 8.3 Hand Installation
.
Do not run the pump against a blocked or restricted outlet.
Please pay close attention to the following symbols throughout this guide:
C
AUTION
:
disregarding may
result in damage to equipment
and
VOIDING OF WARRANTY
W
ARNING
:
disregarding may
result in
SERIOUS INJURY OR
DEATH
Summary of Contents for Solar Pump
Page 1: ...SunRotor Solar Pump Installation and Resource Manual...
Page 36: ......