INFORMATION ABOUT PROPANE (LP) GAS
A self contained LP-gas for use with this appliance must have a capacity of 1.02 lbs. (height 8 inch, 200mm;
diameter 4 inch, 100mm).
The LP-gas supply cylinder to be used must be constructed and marked in accordance with the specifications for
LP-gas cylinders of U.S. Department of Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339
●
This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a
building, garage or any other enclosed space.
●
The propane gas pressure regulator with this appliance must be used. If they do not work, contact the
service center toll free for replacement. .
●
Storage of this appliance indoors is permissible only if the cylinder is disconnect and removed from the
appliance.
●
Cylinders must be stored outdoors out of the reach of children. Disconnected cylinders must have
threaded valve plugs tightly installed and must not be stored in a building, garage or any other
enclosed areas.
,
Outdoor
SPECIFICATIONS
Canadian Standards Association certified to “ANSI Z21.97-201
/
A
Gas Fireplace”
INPUT:
8000
Btu/hr
High
Fire
Propane Regulator Pressure: 11
inches
water column
min
im
um inlet gas supply presure
:
10psi
Maximum
Inlet Gas Supply Pressure: 250 psi
Clearances
to combustible surfaces:
Sides
24" Top 48"