Sunnen GR-2245 Operating Instructions Download Page 1

HOW TO USE

1. Select correct Gage Point 

(see Table1)

.

2. Screw correct range Gage Point (G) into gaging

head 

(see Figure 1)

3. Set gage to desired size, using a ring gage,

micrometer, or Sunnen CF-1000 Dial Bore Gage
Setting Fixture. Set desired size by turning Gage
Point in or out.

NOTE:

If gage nest on your CF-1000 Setting Fixture

has vertical dowel pins, you will have to replace it
with a CF-140 Nest Kit (horizontal dowel pins) in
order to use the CF-1000 with the GR-2245 Gage.

4. Lock Gage Point (G) with Locking Nut (C),

using wrench furnished.

5. Recheck "0" setting; reset to "0" if necessary by

loosening bezel screw, rotating indicator dial face,
and tightening bezel screw.

6. Insert gage into bore to be measured and rock as

shown at "E" to obtain minimum reading.

7. To retract centralizer points and indicator point

squeeze Retract Lever 

(see Figure 2)

.

HOW TO ADJUST:

Adjust Centralizer Points to Bore Size 

-  If

Points don't touch walls of bore, or if they exert too
much pressure on walls, adjust as follows:

1. Insert gaging head approximately 3/4in. (20 mm)

into bore being measured.

2. Insert 5/64in. Hex Wrench into Centralizer Stop

Adjustment. Rotate Wrench to retract or expand
Points until they barely contact walls of bore 

(see

Figure 3)

.

3. Slide gaging head in and out of bore several

times to check adjustment.

NOTE:

The closer Centralizer Points are set to bore

size, the easier it will be to insert gage into bore.

Adjust Worn Centralizer Points  -  

When

Centralizer Points must be adjusted because of
excessive wear, be sure to adjust both Points at
same time. Insert 3/32in. Hex Wrench through both

I-GR-2245D

OPERATING  INSTRUCTIONS

for 

SUNNEN

®

GR-2245 RETRACTABLE DIAL BORE GAGE

DIAMETER RANGE: 2 – 6in. (50 - 150mm)

NOTE:

Metric dimensions shown in these instructions are conversion equivalents only . . . items are not

graduated in metric dimensions unless specifically identified as Metric Models.

http://www.sunnen.com

FIGURE 1

FIGURE 3

FOR DIAMETER RANGE

USE GAGE POINT NO.

INCHES

mm

1

2.000 - 2.375

50 - 60

2

2.375 - 2.750

60 - 70

3

2.750 - 3.125

70 - 79

4

3.125 - 3.500

79 - 89

5

3.500 - 3.875

89 - 98

6

3.875 - 4.250

98 - 108

7 + 2

4.250 - 4.625

108 - 117

7 + 3

4.625 - 5.000

117 - 127

7 + 4

5.000 - 5.375

127 - 137

7 + 5

5.375 - 5.750

137 - 146

7 + 6

5.750 - 6.000

146 - 150

TABLE 1

FIGURE 2

FIGURE 4

Reviews: