Sungrow SG3KTL-M Quick Installation Manual Download Page 1

1.  Turn off the DC switch and then disconnect the
     AC circuit breaker. Prevent them from inadvertently 
     reconnecting during inverter installation.

2.  Secure the backplate to the wall with the  provided
     mounting kits. Hang the inverter to the two recesses
     of the backplate.To protect the inverter from theft,                  
     you can lock it to the backplate with a padlock.

3.  Allow sufficient room around the inverter to 
     enable unobstructed air flow during installation. 
     For multiple inverters installation, positionthe 
     inverters in staggered arrangement.

2

Mounting Inverter onto the Wall

This guide provides a general instruction of the installation procedure of 
SG3KTL-M/SG4KTL-M/SG4K6TL-M/SG5KTL-M.

1

Installation Preparation

Select appropriate cables before securing the inverter to the wall.

SG3KTL-M/SG4KTL-M/SG4K6TL-M/SG5KTL-M 

Quick Installation Guide

EN

Original Version

EN-1

EN-2

EN-3

In no case shall users open the enclosure . Loss of any or all warranty rights may follow if otherwise.

In no case shall this guide substitute for the user manual or related notes on the device. 
Make sure to read over, fully understand and strictly follow the detailed instructions of the user manual and other 
related regulations before installing the equipment.
Any violation could result in personal death or injury or device damage.

DC terminal
RS485 Com. terminal 
PE terminals

AC terminals

SG3KTL-M
SG4KTL-M
SG4K6TL-M
SG5KTL-M
SG3K/4K/4K6/5KTL-M
SG3K/4K/4K6/5KTL-M
SG3K/4K/4K6/5KTL-M

4…6
4…6
4…6
4…6
2.5...6
Shielding Ethernet cable or shielding twist-pair type cable 
-

4
4
6
6
-

6

10…14
10…14
10…14
10…14
5…8

-

10
10
10
10
-

-

Recommended
Value

Range

Recommended
Value

Range

Terminal                                 Type                                  

Cross-sectional Area(mm

2

)

Outer cable diameter(mm)

*  Image here is for reference only. Actual product  you 
    receive may differ.

Install backplate

Hang inverter

Mounting ear

Backplate

•  The theft protection is optional.
•  You shall lock the inverter to the mounted eye plate of  
   the backplate with a suitable (stainless, secured shackle 
   and lock cylinder) padlock.
•  You must ensure that the key is available at all times for 
   possible service purposes.

5. The inverter is equipped with second protective earth terminal as specified in EN 50178. Users may  
     choose to connect PE connection.

The PV input configuration mode should be consistent with the setting in the LCD.

4.  Plug the AC connector into AC terminal placed      
     underneath the inverter. Connect  the “PE” cable
     to the grounding electrode and connect the
     phase cable and “N” cable to the AC circuit 
     breaker as shown on the right.

6. Check the cable polarities of PV input before PV input connection. Connect the DC plug-in connectors 
    to corresponding DC terminals. Connect other PV strings following the same procedures if necessary. 
    Unused DC terminals should be sealed.

The inverter can work on independent mode and parallel mode, you can connect PV input as shown
(In parallel mode, one pair of DC terminals in DC1 input and DC2 input must be short-circuited by 
Y-type cable connector terminal.).

Inverter

AC Grounding Electrode

L

N

L

N

AC Circuit Breaker

PE

PV Arrays 1 

PV Arrays 2

PV Arrays n

Inverter 1

Inverter 2

Inverter n

Grounding Electrode

Copper Bus Bar

Mounting Frame of PV arrays

Grounding of PV Power System

Grounding of Inverter AC Side

 

 

DC1

DC2

 

 

DC1

DC2

+

+
-

-

Independent Mode

Parallel Mode

 

 

 

DC1

DC2

 

 

 

DC1

DC2

+

-

+
+

-
-

SG3KTL-M

SG4K/4K6/5KTL-M

SG4K/4K6/5KTL-M

SG3KTL-M

PV Input Specifications:

RS485/WiFi RS485

AC

ON

DC1

OFF

DC2

AC 
terminal

DC switch 
(Optional)

DC input 
area

RS485 or WiFi 
communication 
terminal

RS485 
communication 
terminal

SG3KTL-M

SG4KTL-M

SG4K6TL-M

SG5KTL-M

DC1

DC2

DC1

DC2

DC1

DC2

DC1

DC2

3200W

3200W

3000W

3500W

3000W

3500W

3000W

3500W

12A

12A

12A

20A

12A

20A

12A

20A

3200W

4300W

4950W

5400W

550V

550V

550V

550V

Type

Area

DC Power Limit 
for Each Input

Total DC Input 
Power Limit

Open-circuit Voltage 
Limit for Each Input

Short-circuit Current 
Limit for Each Input

24A

32A

32A

32A

*The connection parts are not included in the delivery scope.

A

B

C

D

E

Item          Description                    Remark

Screw

Lock washer

Washer

Cable socket

Yellow-green cable

M4×12mm

-

-

-

6mm

2

(9AWG)