SG1K5TL
User Manual
54
8.8
Check Fault-record
The “Fault-record” menu displays the latest fault records, which includes fault type
(see Table 8-5), fault occurring time, fault parameter and fault record number.
Inverter SG1K5TL can store at most 20 fault records.
The latest fault record number is always 01. The oldest fault record number is always
20(suppose there are 20 fault records).
Table 8-5 Fault Type with Simple Explanation
Fault name
Explanation
Vdc-high
DC voltage exceeds maximum DC voltage of inverter.
Vac-high
AC voltage exceeds the upper limit value of grid voltage range.
Vac-low
AC voltage is less than the lower limit value of grid voltage range.
F-fault
Grid frequency exceeds range.
Island
Grid is unavailable or grid malfunction occurs.
PM-FAULT
PM fault occurs.