SG1K5TL
User Manual
30
DC Negative Connector Assembling Procedure:
Step 1:
Unscrew the water-proof terminal in the following direction.
Step 2:
Strip off insulation layer of DC cable and crimp cable core with hand crimping
pliers. The length of strip insulation is approximate 8mm.
Step 3:
Insert appropriately sized DC cable through water-proof terminal.
Step 4:
Plug cable gland into connector housing until it makes a click sound.
Step 5:
Tighten the water-proof terminal in opposite direction.
When connecting connectors, they will be correctly locked in the mating place.
Release the locking part by pressing on the ribbing of the locking hooks and pull them
outwards.
Summary of Contents for SG1K5TL
Page 1: ......
Page 6: ...1 SAFETY AND PRODUCT INFORMATION For Installer and User...
Page 7: ...2...
Page 18: ...13 INSTALLATION AND MAINTENANCE INFORMATION Only for Installer...
Page 19: ...14...
Page 50: ...45 OPERATION INFORMATION For User and Installer...
Page 51: ...46...
Page 55: ...SG1K5TL User Manual 50 8 3 Overview of LCD Menu Fig 8 1 Menu Tree English...