14

5.6

 

Install the single direction valve 

This valve is added especially for our customers, because not many manufacturers add this valve. Before 
you install it please wrap Teflon tape and tighten it with wrench. It could protect the water tank and pipe 
line if the cold water inlet valve is turn off or city water supply is cut off suddenly, because it keeps hot 
solar heated water from backing up into your house plumbing through the cold water line.

 

Note:

 For each connector, customers yourselves need to wrap Teflon tape on it to prevent leakage, and 

make sure that each one is tighten before adding water into the water tank. 

5.7

 

Check and Inspection  

After you finish the assembly of the solar water heater, please check whether every part is ok, after 
inspection, please tighten every bolt. Before you turn on water inlet valve, please make sure that every 
connector is wrapped with Teflon tap and it is tighten. If any leakage, please turn off the water inlet valve 
and drain the water, wrap more Teflon tap on the leakage connector then install and tighten with wrench. 

6

 

Lightning protection 

The solar water heater should have lightning protection to avoid lightening damage. A lightning rod is 
necessary which should be 1.5m higher and 3 m farther away from the solar water heater. For any problems 
that involve plumbing or electrical connections the services of a qualified professional must be employed. 

Warning: 

When in thunderstorm weather please don't use solar water heaters. 

7

 

Precautions 

1)

 

When installing your solar water heater in a cold climate where freezing is possible, please put an 
insulation layer around the pipes which are outside the building. You may want to add additional 
protection in the form of a thermostatically controlled heat tape. 

2)

 

If you use the optional electric immersion heater, the person who installs the electric heater must be a 
qualified electrician. You need to use an electricity leakage protection plug and everything should be 
grounded. 

8

 

Max. working pressure 

This is a pressurized type solar water heater. The maximum working pressure is 6 bar

 

(87PSI). 

 

Summary of Contents for SFH S1 Series

Page 1: ...Version 11 04 For our present For their future...

Page 2: ...8 5 1 4 Assemble tube holder and foot pad 9 5 2 ASSEMBLE THE WATER CYLINDER WATER TANK 10 5 3 ASSEMBLE VACUUM TUBES PLEASE WEAR GLOVES TO PROTECT YOURSELF IN CASE OF A BROKEN TUBE 11 5 3 1 Loosen the...

Page 3: ...f not covered by water Uses a small elbow pipe in the water inlet By doing this the cold water will not mix with the hot water so quickly and the cold water will not flow to the hot water outlet Uses...

Page 4: ...s 58mm 1 8M 170KG 2673 2443 1594 1655 3 How to transport and carry it Please carry the tank horizontally It s forbidden to carry it vertically Please carry the glass tubes carefully and horizontally I...

Page 5: ...15 18 20 24 30 3 Decoration ring for tube 15 18 20 24 30 4 Black silicon tube cup 15 1 18 1 20 1 24 1 30 1 5 Spiral tight clip 15 18 20 24 30 6 Thermal gel 1 1 1 1 1 7 Screw 1 PKG 1 PKG 1 PKG 1 PKG 1...

Page 6: ...om Version 11 04 Subject to change 2011 SUNFLOWER SOLAR 6 4 2 The structure of water tank and connection Fig 4 2 Diameter and length of tube Tube quantity Diameter of water tank Model Series Company l...

Page 7: ...ble side parts Use a pair of M8 12 bolts to connect the gantries front bar standing bar and tie bar 2 tiebar 3 forming the side piece SFH155818 S1 and SFH185818 S1 only has two side pieces You will ne...

Page 8: ...http www sunflower solar com Version 11 04 Subject to change 2011 SUNFLOWER SOLAR 8 5 1 3 Assemble horizontal bars and tie bar 1 Please assemble them by the following steps as shown...

Page 9: ...he tube holder to the front bars using M6 X 10 bolts Join the foot pad to the standing bar and front bar using M6 X 40 bolts The finished frame Assemble the foot pad an 11mm socket or wrench is needed...

Page 10: ...e nuts from the screws at the end of water tank Then two workers hold onto the two ends of the tank and put the tank onto the gantry carefully Please try to let the screws go through the long notch on...

Page 11: ...ng the glass tubes because they can easily be broken and broken tubes can hurt you Fit a black decoration ring on a tube from the open end with the round side facing down Slide this 200mm about 8 inch...

Page 12: ...hange 2011 SUNFLOWER SOLAR 12 4 Tighten the screw and nut of the spiral tight clip so that it can be closed as a ring Install the spiral tight clip uses a 7mm socket wrench or flat blade screw driver...

Page 13: ...r pressure check for leaks If need be using a wrench tighten the immersion heater another 1 4 turn or until the leak stops again being careful not to damage the threads or break the immersion heater I...

Page 14: ...ighten If any leakage please turn off the water inlet valve and drain the water wrap more Teflon tap on the leakage connector then install and tighten with wrench 6 Lightning protection The solar wate...

Page 15: ...igned to withstand wind speeds of up to 100km h 62 mph and 30cm about 11 8 inches of snow accumulation without damage For areas with the possibility for high winds additional reinforcement of attachme...

Reviews: