Bi-Spectrum Radiometric Detector
User Manual
Thermal Parameter Configuration
Issue V1.0 (2019-10-08)
49
Parameter
Description
Setting
mode is selected, the FFC interval (minutes)
ranges from 10 to 255 minutes. The temperature
change of the camera is based on the temperatures
collected by the internal temperature probe. The
temperature of the camera sharply changes when
the camera is powered on. The FFC is relatively
frequent, which is normal.
Manual
: In the manual FFC mode, the camera
does not automatically perform the FFC based on
the temperature change or the specified period.
Choose manual mode, when you feel that the
image is obviously degraded but the automatic
FFC is not performed, you can use the manual
FFC function to check whether the image quality
can be improved.
FFC
Interval
(min)
In the automatic FFC mode, the FFC interval
ranges from 10 to 255 minutes.
[How to set]
Drag the slider.
[Default value]
5
Temper
Interval
In the automatic FFC mode, the FFC interval
ranges from 5 to 25.5 centigrade.
[How to set]
Drag the slider.
[Default value]
5
Shutter
Adjust
Click the icon to adjust exposure immediately.
N/A
Background
Adjust
Click the icon and cover the camera with
something to adjust image. Remove the thing to
finish adjustment.
N/A
----End
5.2.6 Noise Reduction
Figure 5-7 shows the Noise reduction interface.