Thermal Imaging Box Network Camera
User Manual
Thermal Setting
Issue V1.0 (2020-10-28
)
23
Table 3-4
Temperature area and alarm configuration
Parameter
Description
Setting
Channel
N/A
[Setting method]
Select a value from the
drop-down list box.
[Default value]
1
Measure Mode
Set at temperature parameter
interface.
N/A
Name
Area name of temperature area.
[Setting method]
Enter a value manually.
Type
Type of temperature area.
ID 0 is default rectangle area,
which is full screen.
[Setting method]
Select a value from the
drop-down list box.
[Default value]
Rectangle/Point
Alarm Type
Threshold alarm, temperature
difference alarm, section alarm,
temperature rise alarm are
available for alarm type.
Section Alarm: if the
temperature value is among the
set temperature range, it will
generate the alarm.
Temperature rise alarm means it
the rising temperature value is
more than the set value, it will
generate the alarm.
[Setting method]
Select a value from the
drop-down list box.
[Default value]
Threshold alarm
Warning Value
Camera will trigger warning
alarm when the object
temperature reaches the
warning value.
[Setting method]
Enter a value manually.
[Default value]
48
Alarm Value
Camera will alarm when the
object temperature reaches the
alarm value.
[Setting method]
Enter a value manually.
[Default value]
50
Maximum Alarm
Value
At section alarm type, the
device would not alarm when
the temperature is higher than
maximum alarm value.
[Setting method]
Enter a value manually.
[Default value]
60.00